Model reference
U-Line UCLR1215
Ice Maker
1 document14 error codes8 service modes
Available documentation
Service Manual
- User Guide & Service Manual53 pg
MyPros+ Max
Diagnose your U-Line UCLR1215.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (14)
CodeMeaning
10EDoor-related error displayed on control panel.E0Door 1 (upper) open.E1Thermistor 1 (Bin thermistor) is open circuit.E2Thermistor 2 (Condenser/Liquid Line thermistor) is open circuit.E3Thermistor 3 open (does not apply to CLR1215 model).E4Thermistor 4 open (does not apply to CLR1215 model).E5Thermistor 1 (Bin thermistor) is shorted.E6Thermistor 2 (Condenser/Liquid Line thermistor) is shorted.E7Thermistor 3 shorted (does not apply to CLR1215 model).E8Thermistor 4 shorted (does not apply to CLR1215 model).E9Door open errorERDoor-related error displayed on control panel.P1Pump circuit open (does not apply to CLR1215 model).PiPump circuit open.Service modes (8)
- Clean ModeTurn unit on, then hold the CLEAN button for 5 seconds.
- Factory Test Mode (Service Menu #29)Enter service mode, scroll to option 29.
- Ice Thickness Adjustment ModePress and hold the DOWN button for 5 seconds
- Model Number Programming1
- Sabbath ModePress and hold the POWER button until the unit turns off.
- Service ModeHold the hidden button (button 1, leftmost button with no LED above it) for 10 seconds
- Showroom ModeHold the LIGHT key and the POWER key simultaneously for 5 seconds
- Silent ModeHold the UP and DOWN buttons for 3 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related U-Line ice maker models
78,000+ service manuals · 160,000+ error codes · 55+ brands