Error codes (58)
CodeMeaning
E11Water fill difficulty during washing due to closed tap, low water pressure…E13Water leaks detected due to low water pressure, defective pressure switch…E21Drain difficulty during washing due to blocked drain pipe, defective drain…E23Faulty TRIAC for drain pump due to defective wiring, drain pump, or main PCB.E24Drain pump TRIAC sensing circuit faulty; main PCB defective.E31Malfunction in electronic pressure switch circuit due to defective wiring…E32Calibration error of electronic pressure switch due to blocked drain pipe…E35Overflow condition due to defective water inlet valve, kinked pressure switch…E38Internal pressure chamber is clogged; motor belt broken or water circuit on…E41Door open; wiring defective, door safety interlock defective, or main control…E42Problems with door lock; wiring defective, door safety interlock defective…E43Faulty TRIAC supplying power to door delay system; wiring defective, door…E44Faulty sensing by door delay system; main control board defective.E45Faulty sensing by door delay system TRIAC; main control board defective.E52No signal from motor tachometric generator due to wiring problem, defective…E57High current on inverter exceeding 15 A due to faulty wiring on inverter for…E58High current on motor phase exceeding 4.5 A due to motor malfunction, heavy…E59No signal from tachometric generator for 3 seconds due to faulty wiring on…E5AOverheating on heat dissipator for inverter due to open NTC on inverter PCB…E5CInput voltage is too high; voltage out of range, defective inverter board, or…E5DData transfer error between inverter board and main control board due to…E5ECommunication error between inverter board and main control board due to…E5FInverter board fails to start motor due to defective main control board…E5HInput voltage is lower than 175 V; defective inverter board or wiring problem.E62Overheating during washing with temperature exceeding 88°C for more than 5…E66Heating element power relay faulty; main control board defective.E68Current leak to the ground; current leakage between heating element and ground.E69Heating element interrupted; heating element defective, wiring problem, or main…E6AHeating relay sensing faulty; main control board defective.E6HHeating element power relay faulty; earth-leakage between heating element and…View all 58 error codes
E71NTC probe for wash cycle faulty (short-circuited or open); drum water NTC…E74NTC probe for wash cycle improperly positioned; drum water NTC defective…E83Error in reading selector; wrong configuration data loaded or main control…E86Selector configuration error; user interface board defective.E87Display board microprocessor faulty; user interface board defective.E91Communication error between main control board and display board; UI board…E92Communication inconsistency between display and main control board; UI board…E93Appliance configuration error; main control board defective.E94Incorrect configuration of washing cycle; main control board defective.E97Inconsistency between programme selector and cycle configuration; main control…E98Communication error between main control board and inverter board; main circuit…E9CDisplay board configuration error; user interface board defective.E9EDisplay board sensor or touch key faulty; user interface board defective.EC1Electronically controlled valve blocked with operating flowmeter; wiring…EC2Data transfer error between weight sensor and main control board; wiring…EC3Problems with weight sensor (no signal or outside the limits); wiring…EF1Drain filter clogged (drain phase too long); drain filter clogged or drain hose…EF2Overdosing of detergent (too much foam during drain phases); excessive…EF3Aqua control system intervention water pre-fill; water leaks onto base frame or…EF4From flowmeter and electronically controlled valve is open; tap closed or water…EF5Unbalanced load; final spin phases skipped.EF6Control reset.EH1Supply frequency of appliance outside the limits; main circuit board defective…EH2Supply voltage too high; main circuit board defective or fluctuation in input.EH3Supply voltage too low; main circuit board defective or fluctuation in input.EH40 Watt relay malfunction; main circuit board defective.EHEInconsistency between FCV relay and safety sensing circuit; main circuit board…EHFSafety sensing circuit faulty; main circuit board defective or fluctuation in…