Model reference
Viking VGIC530
Range
3 documents12 error codes
Available documentation
Service Manual
- Service Manual Range SMC 0018 VGIC530 and 536 30 and 36 inch Gas38 pg
Bulletin
- Igniter Insulation Sleeve Bulletin1 pg
Service Flash
- Instruction Sheet ISC-0036A for TC-0082A-SP13 pg
MyPros+ Max
Diagnose your Viking VGIC530.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (12)
CodeMeaning
1 flash every 4 secondsNormal operation (idle and active states).2 flashes every 4 secondsControl fault on the DSI module.2 flashes then 4 seconds OFFRTD (Oven Probe) error displayed on cycle light on control panel.3 flashes every 4 secondsIgnition lockout3 flashes then 4 seconds OFFModel Header error displayed on cycle light on control panel.4 flashes every 4 secondsGas solenoid fault.5 flashes every 4 secondsControl fault on the DSI module.6 flashes every 4 secondsGas solenoid fault.7 flashes every 4 secondsPower up with channel on.8 flashes every 4 secondsGas solenoid fault.LED on continuouslyControl fault on the DSI module.No LEDNo power to the DSI (Direct Spark Module)Related Viking range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass