Model reference
Viking DFUW144
Refrigerator
4 documents4 error codes3 service modes
Available documentation
Service Manual
- SMR 0003 Service Manual 2008 24 inch Under the Counter Units25 pg
- Service Manual Refrigerator SMR 0003 Undercounter 24 inch Units25 pg
- Service Manual - 2008 24 Inch Undercounter Refrigeration25 pg
- 2008 24 Inch Undercounter Refrigeration Service Manual25 pg
MyPros+ Max
Diagnose your Viking DFUW144.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (4)
CodeMeaning
E1Compressor fault due to high or low amps detected by the microprocessor.E2Condenser fan motor fault due to high or low amps detected by the…E3Evaporator thermistor (sensor B) fault indicating an out-of-range condition…E4Display thermistor (sensor A) fault indicating an out-of-range condition (open…Service modes (3)
- Sabbath ModePress and hold the 'SET' button while pressing the 'F/C' button four times within seven seconds
- Service Diagnostics ModePress and hold the 'WARMER' button while pressing the 'COLDER' button four times within five…
- Show Room ModePress and hold the 'ON/OFF' button while performing a Power On Reset (POR)
Full entry steps, exit procedures, and test sequences are available in Max.