Model reference
Whirlpool KENMORE
Refrigerator
6 documents25 error codes5 service modes
Available documentation
Tech Sheet
- Kenmore Whirlpool Dryer 110 86742700 Tech Sheet W10143266A12 pg
Wiring Diagram
- Kenmore Whirlpool Refrigerator 110 60852990 Service Wiring Sheet2 pg
Service Flash
- REPAIR TIP R.T. 46-221 - Water Coming Into Ice Maker and Door at Same Time2 pg
Tech Tip
- Defrost Timer Removal - Repair Tip R.T. 46-2092 pg
- Water in the freezer section of Kenmore and Frigidaire Side-by-Side Refrigerators2 pg
Other
- Whirlpool Kenmore Front Load Washer Clean Out Procedure2 pg
MyPros+ Max
Diagnose your Whirlpool KENMORE.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
AFLow inlet air flow detected at install.F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30 V) detected (appears ONLY in Diagnostic…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.L2Low line voltage (less than 30 V) detected at installation.PFPower failure occurred while the dryer was running.Service modes (5)
- Customer-Focused Drying Mode Adjustment1
- Inlet Air Flow Diagnostic1
- Line Voltage Diagnostic1
- Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes…
- Service Diagnostic Test Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass