Model reference
Wolf Appliance SO24ESERIES
Oven
2 documents109 error codes3 service modes
Available documentation
Service Manual
- 24" E Series Oven Service Manual4 pg
- SO24 E Series Oven (SWS 13543126) Service Manual59 pg
MyPros+ Max
Diagnose your Wolf Appliance SO24ESERIES.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (109)
CodeMeaning
E1EEPROM read error, possibly caused by moisture on control board.E10/F0Temperature sensor interruption in the temperature sensor or control board.E100Operating systemE101/F30No communication with control board.E102/F30No communication with relay board.E103/F31Operating systemE104/F31Operating systemE105Operating systemE106Operating systemE107Operating systemE108Operating systemE109Operating systemE11/F0Reference cavity temperature short circuit.E110Operating systemE111/F5Operating systemE112/F5Operating systemE113Operating systemE114Operating systemE115/F29Door lock not initialized.E116Door lock switch error.E117/F29Short in the motor circuit for the door lock.E118/F29Open circuit in the motor for the door lock.E119/F5External firmware error.E12/F0Interruption of the reference cavity temperature.E120/F5SOUNDLIBRARY error.E121/F5PICTURELIBRARY error.E122/F5TEXTLIBRARY error.E123/F5FONTLIBRARY error.E124/F5MODELCONFIGLIBRARY error.E125/F5PRESENTATIONLIBRARY error.View all 109 error codes
E13/F11Cavity temperature over temperature due to temperature sensor, relay error, or…E131/F5FACTORYSETTINGLIBRARY error.E132/F5EASYCOOK data invalid.E133/F32Calibration value error in the water level measurement.E136/F16Thermostat 160C defective.E137/F16Actuator defective; high resistance to element, bake element, broil element, or…E14/F8Critical relay error due to software or mechanical issue.E15/A1Maximum operating time exceeded; cooking mode is canceled if the unit is not…E16/A1Maximum hold time exceeded; operation is put on hold if waiting for operator…E17/F1Food probe temperature short circuit due to food probe, food probe socket, or…E18/F1Food probe temperature open circuit due to open circuit in food probe wires or…E19/F28Door lock not opening due to cavity temperature >572°F, defective door lock, or…E2EEPROM writes error, possibly caused by moisture on control board.E20/F28Door lock not closing due to defective door lock or relay board.E25/F3Short circuit of temperature sensor 300C.E26/F3Open circuit in temperature sensor 300C.E27/F17Over temperature in temperature sensor 300C; temperature limit exceeded…E29/F9Leaking steam due to stuck/defective slider, cooking space not tight, door not…E3EEPROM status error, possibly caused by moisture on control board.E30Real-time clock (RTC) not initialized.E31External RTC error.E32Touch button error due to moisture on control board.E33/F12TemperatureE34/F12TemperatureE35/F13TemperatureE36/F14TemperatureE37/F14TemperatureE38/F15TemperatureE39LCD error due to loose ribbon cable at X15 or connector not locked.E4/F5Control board MAINDATA invalid due to reload software error.E41/F2Short circuit evaporator temperature sensor 100C.E42/F2Open circuit evaporator temperature sensor 100C.E43/F8Neutral relay K1 or K2 stuck; K1 or K2 relay failed self-test.E44/F26Increase in water temperature is slow due to defective evaporator heater…E45/F8Actuator relay K3 stuck due to element or relay board damage.E46/F8Actuator relay K4 stuck due to element or relay board damage.E47/F8Actuator relay K5 stuck due to element or relay board damage.E48/F8Actuator relay K6 stuck due to element or relay board damage.E49/F8Actuator relay K7 stuck due to element or relay board damage.E5/F5Control board MAINDATA incompatible due to reload process error.E50/F25Moisture on the control board due to room air fan not working or steam leak.E51/F6Relay calibration invalid.E52/F10Water tank leaking due to water valve not tight or defective/damaged water…E53RTC calibration invalid.E54/F7Actuator, relay board locked; error E43 to E49 acknowledged 10 times causing…E55Program control data invalid; error only occurs during operation.E56Sequence control data invalid; error only occurs during operation.E57/U0L1 voltage over voltage; voltage at L1 greater than 280 VAC for more than three…E58/U0L2 voltage over voltage; voltage at L2 greater than 280 VAC for more than three…E59/U1L1 voltage under voltage; voltage at L1 was between 155 VAC and 176 VAC.E6/F5Unit model identification invalid.E60/U1L2 voltage under voltage; voltage at L2 was between 155 VAC and 176 VAC or 0…E61L1 voltage high voltage; voltage at L1 was between 260 VAC and 280 VAC for more…E62L2 voltage high voltage; voltage at L2 was between 260 VAC and 280 VAC for more…E63L1 voltage low voltage; voltage at L1 was between 176 VAC and 198 VAC for more…E64L2 voltage low voltage; voltage at L2 was between 176 VAC and 198 VAC for more…E66Thermal cutout tripped; trips at 500°F and resets automatically.E67/F16Thermostat 280C or thermostat 160C tripped; most often a fan or temperature…E68/A1Water tank is leaking.E69/F21Water tank not initialized; sequence errors E70, E71, and E72.E7/F5Relay board MAINDATA invalid due to reload software error.E70/F21Drive switch for the water tank error due to rack and pinion blocked or switch…E71/F21Short circuit in the drive motor for the water tank.E72/F21Open circuit in the drive motor of the water tank.E74/F22Retractable door handle not initialized; sequence errors E74, E75, E76, and E77.E75/F22Retractable door handle switch defective or not mounted correctly.E76/F22Short circuit retractable door handle drive.E77/F22Open circuit retractable door handle drive.E8/F5Relay board MAINDATA incompatible due to reload software error.E81/F23Evaporator draining error due to faulty level measure pin, heavy scale on…E84Slider not initialized; sequence errors E85, E86, and E87.E85/F4Short circuit in stepper motor.E86/F4Open circuit in the stepper motor.E87/F4Slider blocked; slider path restricted during operation.E88Slider in stop position; slider path restricted during operation.E9/F0Temperature sensor short circuit in the temperature sensor or control board.E97Operating systemE98Operating systemE99Operating system
Service modes (3)
- Childproof Lock["Navigate to Settings menu.","Select Set Childproof Lock.","Touch Enter to turn on."]
- Connection Check["Navigate to Settings menu.","Select Check Connection.","Start connection check."]
- Demo Mode["Navigate to Settings menu.","Select Demo Mode.","Enter password 6301.","Turn Demo mode on."]
Full entry steps, exit procedures, and test sequences are available in Max.
Related Wolf Appliance oven models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass