Skip to main content
Error code reference
Amana Range Error Code F6-E1
Over temperature during cook mode (runaway temp).
SourceOven Range - Tech Sheet: Diagnostics & Temperature Adjustment (W10600807A)p. 7
Diagnostic procedure
The full F6-E1 procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Enter Diagnostic Mode, verify codes; cycle bake, broil, and convect elements in test mode; check voltage at P6-1 to P6-3 (120V); check harness wiring.
SourceOven Range - Tech Sheet: Diagnostics & Temperature Adjustment (W10600807A)p. 7
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F6-E1 procedure $9.95
Or subscribe: $29/month for all codes plus Max diagnostics, with 70 Max messages a day. Plus applicable tax.
Where this code is documented
1 manual in the MyPros+ library documents this code for Amana range.
Models covered by the manuals that document this code
- C9W-A/P60330-7WA
- ESR12C-A-P73953-7WA
- EU16K-A/P60250-7WA
- SD19A-A-P60350-7WA
- SD19G-1-A-P60102-7WA
- SD19G-1-A-P60201-7WA
- SDI22F-1-A-P75400-7WA
- SDI25C-A-P73900-7WA
- SDI25E-A-P74100-7WA
- SDI25E-A-P74870-7WA
- SP19W-A-P60340-7WA
- TC18B-A-P73500-7WA
- TCI18D-A-P74660-7WA
- TCI18F-A-P75288-7WA
- TM16D-A-P74645-7WA
- TM16SP-A-P75658-7WA
- TM17G-A-P60101-7WA
- TR16W-A-P60303-7WA
- U13W-A/P60335-7WA
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax