Bosch Dryer Error Code E:7111
COM module (HomeConnect)
COM module (HomeConnect) - D-Bus version protocol mismatch (4-digit equivalent of E:110).
First step from the service manual
Issue eFSB to DLCB; try reflashing the UIM module.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for E:7111.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What E:7111 means on a Bosch dryer
Error code E:7111 on a Bosch dryer signals a D-Bus version protocol mismatch involving the COM module, which is the HomeConnect wireless communication module responsible for enabling the dryer's smart home and remote control functionality. This code is the 4-digit equivalent of E:110 and indicates that the software protocol versions between the COM module and another control module on the D-Bus communication network are incompatible or out of sync. The D-Bus is an internal serial communication bus that allows the dryer's various electronic modules to exchange data, and when protocol versioning does not match between nodes, reliable communication cannot be established.
The first diagnostic action for E:7111 is to issue an eFSB (electronic Field Service Bulletin command) to the DLCB (Download Control Board), followed by an attempt to reflash the UIM (User Interface Module). This process is intended to bring the firmware versions of the involved modules into alignment. A protocol mismatch of this type typically arises after an interrupted or failed over-the-air firmware update, a factory firmware discrepancy between replacement modules, or a corrupted flash memory state in the UIM or COM module. Because the error specifically involves HomeConnect, dryers without active HomeConnect usage may still trigger this fault if the COM module is present and communicating on the D-Bus.
Source: manufacturer service documentation.
Common causes of E:7111
- 01
Interrupted or failed firmware update
Wiring / connectionIf a HomeConnect or dryer firmware update was interrupted mid-process, the COM module or UIM may have been left with an incomplete or mismatched firmware version. This is the most common trigger for a D-Bus protocol mismatch error.
- 02
UIM module firmware corruption
Wiring / connectionThe User Interface Module can develop corrupted flash memory, causing it to report an incorrect protocol version on the D-Bus. Reflashing the UIM via the eFSB process is the primary remediation step for this condition.
- 03
COM module firmware version mismatch
Wiring / connectionThe HomeConnect COM module may be running a firmware version that is incompatible with the current firmware on other modules in the system, particularly after a partial update cycle or module replacement.
- 04
Replacement module with mismatched firmware
Wiring / connectionIf the COM module or UIM was recently replaced, the new component may have shipped with a firmware version that does not match the rest of the dryer's control system. A reflash or firmware alignment procedure is required to resolve this.
- 05
Faulty or failed COM module
Part replacementIf reflashing the UIM and issuing the eFSB command to the DLCB do not resolve the error, the COM module itself may have a hardware fault preventing it from properly negotiating the D-Bus protocol version. Replacement of the COM module would be necessary in this scenario.
Frequently asked questions about E:7111
What does E:7111 mean on a Bosch dryer?
Can I fix E:7111 myself, or do I need a technician?
Is it safe to use my Bosch dryer while it shows E:7111?
Will resetting the dryer clear the E:7111 error?
How much does it cost to repair a Bosch dryer showing E:7111?
78,000+ service manuals · 160,000+ error codes · 55+ brands