mypros+

Bosch Dryer Error Codes

96 error codes for Bosch dryer models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any Bosch dryer error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

E:06Main heating circuitE:08Drum temperature NTC defectiveE:09Heating circuit NTC defectiveE:1Overheating stage 1 (malfunction) due to lint filter, airway, or heat-exchanger…E:109COM module (HomeConnect)E:11Overheating (fluffing) level 1E:110COM module (HomeConnect)E:12Overheating (fluffing) level 2E:13Maximum drying time exceededE:1301RefresherE:1302RefresherE:14Water handling systemE:15Fault in heating circuitE:16SensorsE:167Main heating circuitE:168Operating Unit program configuration does not match Power Unit program…E:17Water handling systemE:18Water handling systemE:2Overheating stage 2 (error) due to lint filter, airway, or heat-exchanger…E:20Control fault 1 (Update invalid)E:2012Heating circuit NTC defectiveE:2013Drum temperature NTC defectiveE:2022Main heating circuitE:2051CompressorE:2080Compressor inverterE:2081Compressor inverterE:2082Compressor inverterE:2083Compressor inverterE:2084Compressor inverterE:2085Compressor inverterE:2087Compressor inverterE:2090CompressorE:20A0Main heating circuitE:20A1Main heating circuitE:20b0Main heating circuitE:21Incorrect checksum; dryer stops and cannot be restarted.E:22Invalid update; dryer stops and cannot be restarted.E:23Model variant doesn't match table; dryer stops and cannot be restarted.E:24Software version doesn't match table; dryer stops and cannot be restarted.E:25Damaged data table; dryer stops and cannot be restarted.E:26Control faultE:27CompressorE:28NTC errorE:29Compressor inverterE:3Condensate tank full (malfunction) / base group full.E:3040Water handling systemE:3050Water handling systemE:3060Water handling systemE:3070Water handling systemE:36Power UnitE:4Time errorE:40Power supplyE:56Operating Unit communication errorE:6Error in drying heater circuit.E:63Power UnitE:67Implausible or missing variant coding.E:7110COM module (HomeConnect)E:7111COM module (HomeConnect)E:8Condenser inlet NTC error (previously displayed as 'door' error).E:8031SensorsE:83RefresherE:85RefresherE:89Power supplyE:9Drying tunnel outlet NTC error (previously displayed as 'heater' error).E:90Power Unit / Safety testE:9002Power supplyE:9003Power supplyE:9024Power supplyE:91Collective error number for all system errors based on reasons of the operating…E:9100Drying cycle time overdueE:92Power supplyE1Water condensate hose is blocked in some way (WTL condensation dryer models…F:04Blocked fluff strainer, air cooler, air circuit, water passages or condensation…F:06Overheating due to blocked fluff strainer, air cooler, or air circuit.F:08Cable break or short-circuit in NTC door sensor.F:09Cable break or short-circuit in NTC heater sensor.

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started