Daewoo Air Conditioner Error Code 2 blink
Compressor or electrical parts of compressor error, OR gas leak.
Compressor or electrical parts of compressor error, OR gas leak.
First step from the service manual
For compressor error, unit continuously works at fixed room temperature 18°C in heating mode. For gas leak, unit continues working. Check compressor operation - at start, if after 5 minutes indoor coil temperature change is below +/-2°C, compressor error is detected (Emergency Mode only).
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 2 blink.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 2 blink means on a Daewoo air conditioner
The 2-blink error code on a Daewoo air conditioner signals either a compressor fault or a refrigerant gas leak. These two root causes share the same error code because both conditions result in the system failing to achieve proper heat exchange at the indoor coil. The control board detects the fault by monitoring indoor coil temperature during startup: if the coil temperature does not change by at least plus or minus 2 degrees Celsius within the first 5 minutes of operation, the system registers the fault and enters Emergency Mode. This diagnostic window is only active during Emergency Mode operation, meaning the unit must be running in that specific state for the detection logic to apply.
When a compressor error is the cause, the unit responds by continuously operating at a fixed room temperature setpoint of 18 degrees Celsius in heating mode, rather than cycling normally based on user settings. This fixed-operation behavior is a protective fallback that keeps some heating function available while preventing further damage. A compressor fault can stem from internal mechanical failure, electrical winding faults, or problems with the compressor's starting and running components such as capacitors or contactors.
When a refrigerant gas leak is the cause, the unit continues to run rather than shutting down, but cooling or heating capacity drops significantly because there is insufficient refrigerant to transfer heat effectively. A leak can occur at flare connections, service valves, or in the coil itself. Both fault types ultimately produce the same symptom at the coil sensor: inadequate temperature change within the detection period, triggering the 2-blink code.
Source: manufacturer service documentation.
Common causes of 2 blink
- 01
Refrigerant gas leak
Part replacementA leak at flare connections, service valves, or the coil reduces the refrigerant charge, preventing adequate heat transfer at the indoor coil. Signs include reduced heating or cooling output and possibly ice buildup on the outdoor unit.
- 02
Compressor mechanical failure
Part replacementInternal mechanical wear or seizure prevents the compressor from pumping refrigerant effectively, resulting in no measurable coil temperature change within the 5-minute detection window.
- 03
Compressor electrical winding fault
Part replacementA shorted or open winding inside the compressor motor causes it to fail to start or run properly. This can be confirmed by checking winding resistance at the compressor terminals.
- 04
Failed start or run capacitor
Part replacementA faulty capacitor can prevent the compressor from starting or sustaining operation, mimicking a full compressor failure. Capacitors should be tested for correct capacitance and replaced if out of specification.
- 05
Indoor coil temperature sensor fault
Part replacementIf the sensor monitoring the indoor coil is reading incorrectly, the control board may incorrectly register no temperature change even when the compressor is working normally. Check sensor resistance against the specified temperature-resistance curve.
Frequently asked questions about 2 blink
What does 2 blink mean on a Daewoo air_conditioner?
Can I fix the 2-blink error on my Daewoo air conditioner myself?
Is it safe to keep running my Daewoo air conditioner when it shows the 2-blink error?
How much does it cost to repair a 2-blink error on a Daewoo air conditioner?
Will resetting my Daewoo air conditioner clear the 2-blink error?
78,000+ service manuals · 160,000+ error codes · 55+ brands