Daewoo Air Conditioner Error Codes
46 error codes for Daewoo air conditioner models. Each links to the full diagnostic procedure from the service manual.
CodeDescription
0 blinks (continuous ON blink)Room sensor open or short1Room air thermistor or connector fault (open/short circuit in room temperature…1 blinkIndoor coil sensor open or short, OR outdoor coil sensor open or short, OR…1 blink (0.5s cycle)Outdoor coil sensor open or short circuit; unit continues working.1 blink (0.5s interval, 8s cycle)Indoor coil sensor open or short circuit; unit does not work.1 blink (8s cycle)Room sensor open or short circuit; unit continues working with fixed room…1 blink (8s interval)Indoor coil sensor open or short, or outdoor coil sensor open or short; unit…1 blink (8s)Indoor coil sensor open or short circuit; unit does not work.1 blink (ON lamp, 0.5s pattern)Indoor coil sensor open or short, OR outdoor coil sensor open or short; unit…1 blink (ON lamp, 8s pattern)Room sensor open or short circuit; unit continues working with room temperature…1 blink (ON lamp)Room sensor open or short circuit1 times blinkRoom sensor open or short circuit; unit continues working with fixed room…2Indoor coil thermistor or connector fault (open/short circuit in evaporator…2 blinkCompressor or electrical parts of compressor error, OR gas leak.2 blinksIndoor coil sensor open or short, OR outdoor coil sensor open or short, OR…2 blinks (0.5s interval, 8s cycle)Outdoor coil sensor open or short, compressor or electrical parts of compressor…2 blinks (0.5s interval)Compressor or electrical parts of compressor error, or gas leak; unit continues…2 blinks (ON lamp, 0.5s pattern)Outdoor coil sensor open or short, compressor or electrical parts of compressor…2 blinks (ON lamp)Compressor or electrical parts of compressor error, or gas leak; unit continues…2 times blinkIndoor coil sensor open or short, outdoor coil sensor open or short, compressor…MyPros+ Max
Get the full diagnostic procedure for any Daewoo air conditioner error code.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts
- Verified part numbers when replacement is required
Get started
$29/month · Cancel anytime · Or $9.95 3-day pass
3Compressor, electrical parts of compressor, or gas leak error4Indoor fan motor, motor connector, or PCB fault.CODE1Room sensor open or short circuitCODE2Indoor coil (I/D) sensor open or short circuitCODE3Outdoor (O/D) sensor open or short circuitCODE4Compressor or electrical parts of compressor errorCODE5Communication error between indoor unit (I.D.U) and outdoor unit (O.D.U), or…CODE64-way valve or electrical parts of 4-way valve errorCODE7Operation mode is different between the two indoor units.continuous blinkUnit does not work due to indoor coil sensor open/short, outdoor coil sensor…continuous ON blinkRoom sensor open or shortContinuous ON lamp blinkRoom sensor open or short circuit; unit continues working with room temperature…E1Room sensor open or short circuit detected (ON lamp blinks continuously for 8…E2Indoor coil sensor or outdoor coil sensor open or short circuit (ON lamp does…E3Compressor or electrical parts of compressor errorE4Gas leak detectedLED 1 time blinkGas leak detected; unit continuously working.LED 3 times blinkCompressor or electrical parts of compressor error; unit continuously works to…LED 8s blinkRoom sensor open or short circuit, indoor coil sensor open or short, or outdoor…ON LAMP 1 blink (8s interval)Indoor coil sensor open or short, or outdoor coil sensor open or short; unit…ON LAMP 2 blinks (0.5s interval)Compressor or electrical parts of compressor error, or gas leak; unit continues…ON LAMP Blink (0.5s, 2 times blink)Outdoor coil sensor open or short, compressor or electrical parts of compressor…ON LAMP Blink (8s, 1 times blink)Outdoor coil sensor open or short circuit; unit continues working.ON LAMP Blink (continuous)Room sensor open or short circuit; unit continues working with room temperature…ON lamp continuous blinkRoom sensor open or short circuitRoom Sensor open/shortRoom temperature sensor is open or shorted; unit continues working with room…