mypros+
Error code reference

Daewoo Air Conditioner Error Code ON LAMP 2 blinks (0.5s interval)

Compressor or electrical parts of compressor error, or gas leak; unit continues working.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the ON LAMP 2 blinks (0.5s interval) error code actually means

Your Daewoo air conditioner has detected a problem with the compressor or a possible refrigerant leak, and it is using the ON lamp to warn you by blinking twice repeatedly. The unit is still running, but it needs to be inspected by a technician before the problem gets worse. Ignoring this warning could lead to reduced cooling performance or eventual system damage.

Diagnostic procedure

The full ON LAMP 2 blinks (0.5s interval) procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check voltage between L and Y of terminal block; check connecting wire between indoor and outdoor units; check relay RL1 on power PCB; check gas leakage of the pipe.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock ON LAMP 2 blinks (0.5s interval) procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of ON LAMP 2 blinks (0.5s interval)

Ranked by how often they cause this code
  1. 1Faulty or failed relay RL1 on power PCB
  2. 2Refrigerant gas leak
  3. 3Incorrect voltage between terminals L and Y
  4. 4Damaged or broken connecting wire between indoor and outdoor units
  5. 5Compressor electrical component failure

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about ON LAMP 2 blinks (0.5s interval)

What does ON LAMP 2 blinks (0.5s interval) mean on a Daewoo air_conditioner?
This blink pattern indicates a compressor or compressor electrical component fault, or a refrigerant gas leak in the system. The ON lamp flashing twice at 0.5-second intervals is the unit's way of alerting you to a condition in the outdoor unit or refrigerant circuit. Importantly, the unit continues to operate while this code is active, so the warning may be easy to overlook. A technician should inspect the terminal block voltage, connecting wires, relay RL1 on the power PCB, and the refrigerant lines as the first steps.
Is it safe to keep running my Daewoo air conditioner when the ON LAMP is blinking twice?
The unit is designed to continue operating when this code is active, but running the system with a potential refrigerant leak or compressor electrical fault can cause additional damage over time. A low refrigerant level puts extra stress on the compressor, which can lead to premature compressor failure. It is best to have the unit inspected promptly rather than continuing to run it indefinitely with the fault present.
How much does it cost to repair the ON LAMP 2 blinks fault on a Daewoo air conditioner?
Repair costs depend heavily on the root cause identified during diagnosis. Replacing relay RL1 on the power PCB is typically among the less expensive repairs, while repairing a refrigerant leak and recharging the system involves both parts and refrigerant costs that can push the total higher. Compressor electrical component failures or full compressor replacement represent the higher end of the cost range. Expect diagnostic fees plus parts and labor costs that can range from modest to several hundred dollars depending on what is found.
Can I fix the ON LAMP 2 blinks error on my Daewoo air conditioner myself?
Some parts of the diagnosis, such as visually inspecting the connecting wires between the indoor and outdoor units for obvious damage, can be done without special tools. However, measuring terminal block voltage, testing relay RL1, and checking for refrigerant leaks require electrical knowledge and, in the case of refrigerant work, certification to handle refrigerants legally. It is strongly recommended to have a qualified technician handle the electrical and refrigerant components of this diagnosis.
Will resetting my Daewoo air conditioner clear the ON LAMP 2 blinks error?
A power reset may temporarily clear the displayed fault, but it will not resolve the underlying cause. If the compressor circuit issue, wiring fault, relay problem, or refrigerant leak is still present, the code will return once the system resumes normal operation. Resetting without diagnosis is not a fix and could delay identifying a worsening condition.