Daewoo Air Conditioner Error Code ON LAMP 2 blinks (0.5s interval)
Compressor or electrical parts of compressor error, or gas leak; unit continues working.
Compressor or electrical parts of compressor error, or gas leak; unit continues working.
First step from the service manual
Check voltage between L and Y of terminal block; check connecting wire between indoor and outdoor units; check relay RL1 on power PCB; check gas leakage of the pipe.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for ON LAMP 2 blinks (0.5s interval).
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What ON LAMP 2 blinks (0.5s interval) means on a Daewoo air conditioner
The ON LAMP blinking twice at 0.5-second intervals on a Daewoo air conditioner signals a compressor or compressor electrical component fault, or a refrigerant gas leak. Despite the fault detection, the unit continues operating, which means the system has not fully shut down but is alerting technicians that a condition exists that requires investigation. This code points specifically to the outdoor unit's compressor circuit and the refrigerant circuit as the primary areas of concern.
The diagnostic process begins at the terminal block, where voltage between terminals L and Y must be measured to confirm proper electrical supply and signal communication between the indoor and outdoor units. A wiring fault or break in the connecting wires between the two units can produce this error by disrupting the control signals that monitor compressor operation. Relay RL1 on the power PCB is a critical component in this circuit, responsible for controlling compressor energization. A failed, stuck, or intermittently faulty RL1 relay can cause incorrect compressor operation signals, triggering the blink code.
Refrigerant gas leakage is also a listed cause for this fault. A low refrigerant charge can cause abnormal compressor behavior, including elevated current draw, overheating, or erratic cycling, all of which can register as a compressor error. Inspecting the refrigerant lines, fittings, and coil connections for signs of oil residue or frost is part of the gas leak evaluation. A proper leak check using appropriate detection equipment is required before any refrigerant is added.
Source: manufacturer service documentation.
Common causes of ON LAMP 2 blinks (0.5s interval)
- 01
Faulty or failed relay RL1 on power PCB
Part replacementRelay RL1 controls compressor operation through the power PCB. If the relay has failed open, is sticking, or is making intermittent contact, the control board will detect an abnormal compressor state and trigger the blink code.
- 02
Refrigerant gas leak
Part replacementA leak in the refrigerant circuit reduces the charge level, causing the compressor to operate under abnormal load conditions. Look for oil residue around pipe fittings, flare connections, and the outdoor coil as visual indicators.
- 03
Incorrect voltage between terminals L and Y
Wiring / connectionIf the measured voltage between the L and Y terminals on the terminal block is out of range, the outdoor unit may not be receiving the correct control signal, which can cause compressor communication errors and trigger this code.
- 04
Damaged or broken connecting wire between indoor and outdoor units
Part replacementThe control wiring linking the indoor and outdoor units carries signals used to monitor and control compressor operation. A broken, shorted, or corroded wire in this harness can disrupt communication and produce this fault code.
- 05
Compressor electrical component failure
Part replacementInternal compressor electrical components, including motor windings or capacitors, can degrade or fail, resulting in abnormal electrical characteristics that the control system flags as a compressor error.
Frequently asked questions about ON LAMP 2 blinks (0.5s interval)
What does ON LAMP 2 blinks (0.5s interval) mean on a Daewoo air_conditioner?
Can I fix the ON LAMP 2 blinks error on my Daewoo air conditioner myself?
Is it safe to keep running my Daewoo air conditioner when the ON LAMP is blinking twice?
Will resetting my Daewoo air conditioner clear the ON LAMP 2 blinks error?
How much does it cost to repair the ON LAMP 2 blinks fault on a Daewoo air conditioner?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass