Daewoo Air Conditioner Error Code ON LAMP 2 blinks (0.5s interval)

Compressor or electrical parts of compressor error, or gas leak; unit continues working.

Compressor or electrical parts of compressor error, or gas leak; unit continues working.

First step from the service manual

Check voltage between L and Y of terminal block; check connecting wire between indoor and outdoor units; check relay RL1 on power PCB; check gas leakage of the pipe.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for ON LAMP 2 blinks (0.5s interval).

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What ON LAMP 2 blinks (0.5s interval) means on a Daewoo air conditioner

The ON LAMP blinking twice at 0.5-second intervals on a Daewoo air conditioner signals a compressor or compressor electrical component fault, or a refrigerant gas leak. Despite the fault detection, the unit continues operating, which means the system has not fully shut down but is alerting technicians that a condition exists that requires investigation. This code points specifically to the outdoor unit's compressor circuit and the refrigerant circuit as the primary areas of concern.

The diagnostic process begins at the terminal block, where voltage between terminals L and Y must be measured to confirm proper electrical supply and signal communication between the indoor and outdoor units. A wiring fault or break in the connecting wires between the two units can produce this error by disrupting the control signals that monitor compressor operation. Relay RL1 on the power PCB is a critical component in this circuit, responsible for controlling compressor energization. A failed, stuck, or intermittently faulty RL1 relay can cause incorrect compressor operation signals, triggering the blink code.

Refrigerant gas leakage is also a listed cause for this fault. A low refrigerant charge can cause abnormal compressor behavior, including elevated current draw, overheating, or erratic cycling, all of which can register as a compressor error. Inspecting the refrigerant lines, fittings, and coil connections for signs of oil residue or frost is part of the gas leak evaluation. A proper leak check using appropriate detection equipment is required before any refrigerant is added.

Source: manufacturer service documentation.

Common causes of ON LAMP 2 blinks (0.5s interval)

  1. 01

    Faulty or failed relay RL1 on power PCB

    Part replacement

    Relay RL1 controls compressor operation through the power PCB. If the relay has failed open, is sticking, or is making intermittent contact, the control board will detect an abnormal compressor state and trigger the blink code.

  2. 02

    Refrigerant gas leak

    Part replacement

    A leak in the refrigerant circuit reduces the charge level, causing the compressor to operate under abnormal load conditions. Look for oil residue around pipe fittings, flare connections, and the outdoor coil as visual indicators.

  3. 03

    Incorrect voltage between terminals L and Y

    Wiring / connection

    If the measured voltage between the L and Y terminals on the terminal block is out of range, the outdoor unit may not be receiving the correct control signal, which can cause compressor communication errors and trigger this code.

  4. 04

    Damaged or broken connecting wire between indoor and outdoor units

    Part replacement

    The control wiring linking the indoor and outdoor units carries signals used to monitor and control compressor operation. A broken, shorted, or corroded wire in this harness can disrupt communication and produce this fault code.

  5. 05

    Compressor electrical component failure

    Part replacement

    Internal compressor electrical components, including motor windings or capacitors, can degrade or fail, resulting in abnormal electrical characteristics that the control system flags as a compressor error.

See the test procedure for each cause

Frequently asked questions about ON LAMP 2 blinks (0.5s interval)

What does ON LAMP 2 blinks (0.5s interval) mean on a Daewoo air_conditioner?
This blink pattern indicates a compressor or compressor electrical component fault, or a refrigerant gas leak in the system. The ON lamp flashing twice at 0.5-second intervals is the unit's way of alerting you to a condition in the outdoor unit or refrigerant circuit. Importantly, the unit continues to operate while this code is active, so the warning may be easy to overlook. A technician should inspect the terminal block voltage, connecting wires, relay RL1 on the power PCB, and the refrigerant lines as the first steps.
Can I fix the ON LAMP 2 blinks error on my Daewoo air conditioner myself?
Some parts of the diagnosis, such as visually inspecting the connecting wires between the indoor and outdoor units for obvious damage, can be done without special tools. However, measuring terminal block voltage, testing relay RL1, and checking for refrigerant leaks require electrical knowledge and, in the case of refrigerant work, certification to handle refrigerants legally. It is strongly recommended to have a qualified technician handle the electrical and refrigerant components of this diagnosis.
Is it safe to keep running my Daewoo air conditioner when the ON LAMP is blinking twice?
The unit is designed to continue operating when this code is active, but running the system with a potential refrigerant leak or compressor electrical fault can cause additional damage over time. A low refrigerant level puts extra stress on the compressor, which can lead to premature compressor failure. It is best to have the unit inspected promptly rather than continuing to run it indefinitely with the fault present.
Will resetting my Daewoo air conditioner clear the ON LAMP 2 blinks error?
A power reset may temporarily clear the displayed fault, but it will not resolve the underlying cause. If the compressor circuit issue, wiring fault, relay problem, or refrigerant leak is still present, the code will return once the system resumes normal operation. Resetting without diagnosis is not a fix and could delay identifying a worsening condition.
How much does it cost to repair the ON LAMP 2 blinks fault on a Daewoo air conditioner?
Repair costs depend heavily on the root cause identified during diagnosis. Replacing relay RL1 on the power PCB is typically among the less expensive repairs, while repairing a refrigerant leak and recharging the system involves both parts and refrigerant costs that can push the total higher. Compressor electrical component failures or full compressor replacement represent the higher end of the cost range. Expect diagnostic fees plus parts and labor costs that can range from modest to several hundred dollars depending on what is found.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass