Daewoo DSB-181L
Air Conditioner
13 documents22 error codes5 service modes
Available documentation
Service Manual
- Service Manual Model: DSB-181L50 pg
- DAEWOO DSB181L Service Manual CDC 48160 pg
- Daewoo DSB F123L E Service Manual CDC 143262 pg
- Daewoo DSB 070 091 121 122 240 LH CDC 1573 Service Manual96 pg
- Service Manual Split System Air Conditioner79 pg
- Daewoo DSB 123L E Service Manual CDC 143256 pg
- Service Manual Split System Air Conditioner Model: DSB-F183L59 pg
- Daewoo DSB070LH10 Service Manual96 pg
- Service Manual Split System Air Conditioner Model: DSB-F092L61 pg
- Daewoo DSB-F071L / DSB-F092L Service Manual103 pg
- Service Manual Split System Air Conditioner Model: DSB-F071L62 pg
- DAEWOO DSB240L Service Manual CDC 48196 pg
- Service Manual Split System Air Conditioner134 pg
MyPros+ Max
Diagnose your Daewoo DSB-181L.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (22)
CodeMeaning
1Room air thermistor or connector fault (open/short circuit in room temperature…1 blinkRoom sensor open or short circuit; unit continuously operates at fixed room…1 blink (0.5s cycle)Outdoor coil sensor open or short circuit; unit continues working.1 blink (8s cycle)Room sensor open or short circuit; unit continues working with fixed room…1 blink (8s interval)Indoor coil sensor open or short, or outdoor coil sensor open or short; unit…1 blink (8s)Indoor coil sensor open or short circuit; unit does not work.2Indoor coil thermistor or connector fault (open/short circuit in evaporator…2 blinksIndoor coil sensor open or short, outdoor coil sensor open or short, compressor…2 blinks (0.5s interval)Compressor or electrical parts of compressor error, or gas leak; unit continues…3Compressor, electrical parts of compressor, or gas leak fault (displayed in…continuous blinkUnit does not work due to indoor coil sensor open/short, outdoor coil sensor…Continuous ON lamp blinkRoom sensor open or short circuit; unit continues working with room temperature…LED 1 time blinkGas leak detected; unit continuously working.LED 3 times blinkCompressor or electrical parts of compressor error; unit continuously works to…LED 8s blinkRoom sensor open or short circuit, indoor coil sensor open or short, or outdoor…ON LAMP 1 blink (8s interval)Indoor coil sensor open or short, or outdoor coil sensor open or short; unit…ON LAMP 2 blinks (0.5s interval)Compressor or electrical parts of compressor error, or gas leak; unit continues…ON LAMP Blink (0.5s, 2 times blink)Compressor or electrical parts of compressor error, or gas leak.ON LAMP Blink (8s, 1 times blink)Outdoor coil sensor open or short circuit; unit continues working.ON LAMP Blink (continuous)Room sensor open or short circuit; unit continues working with fixed room…ON LAMP continuous blinkRoom sensor open or short circuit; unit continues working with fixed room…Room Sensor open/shortRoom temperature sensor is open or shorted; unit continues working with room…Service modes (5)
- Emergency Operation["Set the select switch on the switch panel to the Emergency position (away from Remote).","Unit…
- Self-DiagnosticThe control automatically contains diagnostic tests to verify system integrity
- Test Operating["Activate test operating mode (details not further specified in document)."]
- Test Operating ModeActivate test operating mode (details not specified beyond referencing test operation).
- Test Operation["Activate test operating mode (via test/emergency switch on indoor unit)."]
Full entry steps, exit procedures, and test sequences are available in Max.