Daikin Air Conditioner Error Code C1

Transmission error between indoor unit PCB and fan PCB (FBQ only).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the C1 error code actually means

Your Daikin air conditioner has detected a communication problem between two of its internal circuit boards that control the fan. This usually means a wiring connector has come loose inside the unit. A technician will need to open the indoor unit and check the connection between those boards to resolve the issue.

Diagnostic procedure

The full C1 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if connector between indoor unit PCB (A1P) and fan PCB (A2P) is accurately connected.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock C1 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of C1

Ranked by how often they cause this code
  1. 1Loose or disconnected connector between A1P and A2P
  2. 2Damaged wiring harness between the two PCBs
  3. 3Corroded or contaminated connector pins
  4. 4Failed fan PCB (A2P)
  5. 5Failed indoor unit main PCB (A1P)

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about C1

What does C1 mean on a Daikin air_conditioner?
The C1 error code on a Daikin FBQ-series air conditioner signals a transmission error between the indoor unit main PCB (A1P) and the fan PCB (A2P). These two boards must communicate continuously for the system to operate the fan correctly. When that communication is lost or corrupted, the unit shuts down and displays C1. This fault is specific to the FBQ ducted unit range.
Will resetting my Daikin unit clear the C1 error code?
A power reset may temporarily clear the C1 code, but if the underlying communication fault between the two PCBs still exists, the error will return once the unit attempts to operate. The root cause, whether a loose connector, damaged wiring, or a faulty board, must be physically corrected for the fault to stay resolved.
How much does it cost to repair a C1 error on a Daikin FBQ unit?
Repair costs vary depending on the root cause. If the fix is simply reseating a loose connector, you may only pay for a service call, typically in the range of $80 to $200 depending on your location. If the fan PCB or main control board needs replacement, parts and labor combined can range from $300 to $800 or more, depending on parts availability and the specific model.
How do I fix the C1 error on my Daikin air conditioner?
Start by having a technician inspect the connector between the indoor unit PCB (A1P) and the fan PCB (A2P) to confirm it is fully and securely seated. If the connector is intact, the next steps are inspecting the wiring harness for damage and checking connector pins for corrosion. If wiring and connectors are in good condition, one or both PCBs may need to be replaced.
Is it safe to keep running my Daikin air conditioner with a C1 error?
Continuing to operate the unit with an active C1 fault is not recommended. The error indicates the main control board cannot reliably communicate with the fan PCB, which means fan operation may be unpredictable or absent. Running the system in this state risks inadequate cooling and could contribute to further component damage.