Daikin Air Conditioner Error Code CC

Humidity sensor system abnormality

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CC error code actually means

Your Daikin air conditioner has detected a problem with its humidity sensor, which may have come unplugged or developed a fault. The good news is that your unit will keep running normally even while this error is active. A technician can usually fix this by reseating or replacing the sensor, which is a relatively straightforward repair.

Diagnostic procedure

The full CC procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Remove humidity sensor from indoor unit PCB and reinsert; check if it functions normally.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CC procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CC

Ranked by how often they cause this code
  1. 1Loose or disconnected sensor connector
  2. 2Shorted humidity sensor
  3. 3Moisture or corrosion at sensor connector
  4. 4Damaged sensor wiring
  5. 5Faulty indoor PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CC

What does CC mean on a Daikin air_conditioner?
The CC error code on a Daikin FCQ series air conditioner indicates a humidity sensor system abnormality. The indoor unit PCB has detected that the humidity sensor is either disconnected or has a short circuit. This code is exclusive to FCQ series units. Importantly, the system continues to operate while this fault is active, so cooling or heating function is not immediately lost.
Is it safe to keep running my Daikin unit while the CC code is showing?
Yes, the Daikin FCQ unit is designed to continue operating when the CC code is active. The system does not shut down due to this fault. However, any humidity-based control functions that rely on sensor input may not operate correctly until the sensor issue is resolved, so the fault should still be addressed in a timely manner.
Will resetting my Daikin unit clear the CC error code?
A simple power reset may temporarily clear the CC code from the display, but if the underlying issue with the humidity sensor or its connection is still present, the fault will return during operation. A lasting resolution requires physically inspecting and correcting the sensor connection, or replacing the faulty component.
Can I fix the CC error code myself?
The first recommended step is to access the indoor unit, carefully remove the humidity sensor from its connector on the PCB, and reinsert it firmly. If the sensor was simply loose, this reseating process may clear the fault. If the error persists after reseating, further diagnosis involving sensor testing or component replacement is best handled by a qualified technician.
How much does it cost to repair the CC error on a Daikin unit?
If the fault is caused by a loose connector, the repair cost is primarily the technician's diagnostic and labor fee, typically in the range of $75 to $150 depending on your location. If the humidity sensor itself needs replacement, parts and labor combined generally range from $150 to $350. PCB replacement, if required, would be a more significant expense.