Daikin Air Conditioner Error Code E1

Outdoor unit PCB abnormality

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E1 error code actually means

Your Daikin air conditioner's outdoor unit has detected a problem with the computer chip that stores its operating settings, and it cannot read the information it needs to run safely. This could be a temporary glitch caused by a power fluctuation, or it could indicate a faulty control board in the outdoor unit. Turning the system off and back on is the first step to see if the problem clears on its own.

Diagnostic procedure

The full E1 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Turn power off then on again to check if normal operation resumes.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E1 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E1

Ranked by how often they cause this code
  1. 1Transient EEPROM read failure after power disruption
  2. 2Corrupted EEPROM data
  3. 3Failed outdoor unit PCB
  4. 4Loose or corroded PCB connections
  5. 5Voltage supply issue to outdoor unit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E1

What does E1 mean on a Daikin air_conditioner?
The E1 code on a Daikin air conditioner indicates an outdoor unit PCB abnormality where the EEPROM data could not be correctly received by the control board. The EEPROM stores essential operating parameters for the outdoor unit, and if the board cannot read this data, the system will not operate. This fault can be caused by a temporary communication error, corrupted memory data, or a failed outdoor unit PCB.
Is it safe to keep running my Daikin unit when E1 is displayed?
When the E1 error is active, the Daikin system will typically shut down and refuse to operate, so running the unit is generally not possible in this state. This is a protective response to prevent operation with missing or incorrect configuration data. Do not attempt to bypass or override the fault, as operating with incorrect parameters could damage the system.
Can I replace the outdoor unit PCB myself to fix the E1 error?
Replacing the outdoor unit PCB involves working with high-voltage components and requires disconnecting and correctly reconnecting multiple wiring harnesses, which carries serious risk of electrical injury if done incorrectly. In most jurisdictions, work on the electrical components of air conditioning systems should be performed by a licensed technician. Additionally, proper diagnosis is needed to confirm the PCB is actually faulty before purchasing a replacement board, as other causes such as supply voltage issues may produce the same error.
Will resetting my Daikin air conditioner clear the E1 error?
Turning the power off and back on is the recommended first diagnostic step and may clear the E1 error if the fault was caused by a transient power disruption or temporary communication issue. If the error returns immediately after the reset or persists across multiple power cycles, the EEPROM data may be permanently corrupted or the outdoor unit PCB may have failed, requiring professional diagnosis and likely board replacement.
How much does it cost to fix a Daikin E1 error?
If the issue resolves with a simple power reset, there is no parts cost, though a service call fee may apply if a technician performs the diagnosis. If the outdoor unit PCB requires replacement, parts and labor costs typically range from $300 to $700 or more depending on the unit model, board availability, and local labor rates. Getting a quote from a certified Daikin technician before authorizing repairs is recommended.