What the U3 error code actually means

Your Daikin air conditioner is showing this error because a required startup test was never completed after the unit was installed or serviced. This test checks that everything is connected and working correctly before the system runs normally. A technician needs to run this test using the service board on the unit to clear the error and allow the system to operate.

Diagnostic procedure

The full U3 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Press and hold BS4 on service PCB for 5 seconds to conduct check operation.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock U3 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of U3

Ranked by how often they cause this code
  1. 1Check operation skipped after new installation
  2. 2Check operation skipped after refrigerant service
  3. 3PCB replacement without recommissioning
  4. 4Power interruption during original check operation
  5. 5Firmware or memory reset on control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about U3

What does U3 mean on a Daikin air_conditioner?
The U3 code means the unit was started without completing the required check operation, which is a commissioning procedure that must be performed before a Daikin system is placed into regular service. This code is not a hardware failure but a procedural flag indicating the system has not been properly commissioned. It commonly appears after a new installation, refrigerant service, or control board replacement. A technician can resolve it by pressing and holding button BS4 on the service PCB for 5 seconds to initiate the check operation.
Will resetting the power clear the U3 error on a Daikin unit?
No, a simple power reset will not clear the U3 error. The code will return because the underlying condition, the incomplete check operation, has not been addressed. The only way to resolve U3 is to complete the check operation using the BS4 button on the service PCB. Power cycling without completing this procedure will result in the unit displaying U3 again once it restarts.
How much does it cost to fix a U3 error on a Daikin air conditioner?
Because U3 is typically a procedural issue rather than a parts failure, the cost is usually limited to a service call fee for a technician to complete the check operation. Service call rates generally range from $75 to $200 depending on location and provider. If the code was triggered by a prior repair such as a board replacement or refrigerant recharge, the recommissioning may be included as part of that service. No replacement parts are typically needed to resolve U3 on its own.
How do I fix the U3 error on my Daikin air conditioner?
To fix U3, the check operation must be completed by pressing and holding the BS4 button on the service PCB for at least 5 seconds. This initiates a diagnostic commissioning sequence the system requires before operating normally. Because this involves accessing the service PCB inside the unit, it should be performed by a qualified HVAC technician. Before running the check operation, verify that all wiring and refrigerant connections are correct to avoid triggering additional fault codes during the procedure.
Is it safe to keep running a Daikin air conditioner showing a U3 error?
A U3 error means the unit has not been fully commissioned, so it may operate in a restricted or unverified state. Running the system without completing the check operation means its refrigerant charge, wiring, and configuration have not been confirmed as correct. This could result in reduced efficiency or potential issues going undetected. It is advisable to have the check operation completed promptly rather than continuing to run the unit in an uncommissioned state.