GE Café Refrigerator Error Codes

72 error codes for GE Café refrigerator models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any GE Café refrigerator error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

0201Refrigerator defrost heater on for max time.0202Five consecutive freezer abnormal defrosts.0203Five consecutive refrigerator abnormal defrosts.0300Excessive compressor run time.0301Cooling system was on and the compressor remained off for 3-hours.0303Refrigerator temperature exceeded (setpoint + 20°F).0304Freezer temperature exceeded (setpoint + 20°F).03083-way valve lost.0311Convertible drawer damper stuck closed.0312Convertible drawer damper stuck open.0313Convertible drawer temperature exceeded (setpoint + 20°F).0314Convertible drawer freezing when set to warm.03153-way valve cooling not detected in refrigerator evaporator.03163-way valve cooling not detected in freezer evaporator.0400DC voltage out of range.0403Main control board software fault (replace board).0404Main control board hardware fault (replace board).0501Flow meter signal missing.0502Flow meter pulsing with no water dispense.0503Ice/water stops dispensing based on time (7-minute time out).0507Paddle switch input missing when main board has received a message it was…0508Paddle switch input present when main board has not received a message it was…0511Ice mold temperature invalid.0512Ice box thermistor temperature invalid.0515Door board relay driver is shorted (replace door board).0601Ice maker harvest > 10-minutes.06023 out of last 10 ice maker harvests were > 10-minutes.0603Ice maker harvest not complete after 30-minutes.0604Ice maker no water supply detected.0605Ice maker continues to sense a full bucket after an ice dispense.0700Stuck keys on dispenser board.0713A refrigerator door opens for 15 minutes without being closed.0714A refrigerator door opens for 60 minutes in the last 24-hours.0715100 left door openings in the last 24-hours.0716100 right door openings in the last 24-hours.0717Freezer drawer open for 15 minutes continuously.0718Freezer drawer open for 60 total minutes in the last 24-hours.0719100 freezer drawer openings in the last 24-hours.0721AutoFill sensors detect an object present over several hours; sensors may be…0722AutoFill initialization failed.0723Capacitive touch controlled reset.0726Convertible drawer opens for 15-minutes without closing.0727Convertible drawer opens for 60-minutes in the last 24-hours.0728100 convertible drawer openings in the last 24-hours.0729Stuck keys on convertible drawer board.0731Convertible drawer board communication error.0732Door board communication error.0733Dispenser board communication error.0737AutoFill termination by no water level change.0738AutoFill terminated by keypad before fill completed.0739AutoFill terminated by target removal before fill completed.0740AutoFill terminated by EMI noise.

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started