What the 2+6 error code actually means

Your Lennox furnace detected that a safety sensor, called a pressure switch, was already triggered before the blower that moves exhaust gases even turned on. This is not the expected sequence, so the furnace stopped itself to avoid a potentially unsafe condition. A technician will need to check whether the sensor is stuck, there is moisture in the sensor tubing, or there is a blockage somewhere in the exhaust system.

Diagnostic procedure

The full 2+6 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 2+6 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 2+6

Ranked by how often they cause this code
  1. 1Failed or stuck pressure switch
  2. 2Moisture or condensate in pressure sensing tubing
  3. 3Blocked or kinked pressure switch tubing
  4. 4Flue or vent obstruction
  5. 5Faulty inducer assembly

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 2+6

What does 2+6 mean on a Lennox furnace?
Code 2+6 on a Lennox furnace means the high fire pressure switch was detected in the closed position before the combustion air inducer was activated. This is a safety fault because the pressure switch should only close after the inducer starts and builds adequate draft. The furnace shuts down the ignition sequence to prevent unsafe operation until the underlying cause is resolved.
Is it safe to keep running my furnace with a 2+6 error code?
No. The furnace will typically refuse to complete a heating cycle when this code is active, which is intentional. The pressure switch system is a safety control that helps ensure combustion gases are properly vented. Operating the furnace while bypassing or ignoring this fault could result in incomplete combustion or improper venting, which poses a safety risk. The fault should be diagnosed and corrected before resuming normal operation.
How much does it cost to repair a Lennox furnace showing a 2+6 error?
Repair costs depend on the root cause. Clearing a blocked or moisture-filled pressure sensing tube may only involve a service call fee, typically in the range of $75 to $150. Replacing a faulty pressure switch generally costs between $100 and $250 including parts and labor. If the inducer motor or assembly requires replacement, costs can range from $300 to $700 or more depending on the specific model and local labor rates.
Can I fix a Lennox furnace 2+6 error code myself?
Some causes, such as moisture or a visible kink in the pressure switch tubing, can be addressed by a knowledgeable DIYer after powering down the furnace. However, testing pressure switch continuity, diagnosing inducer performance, and evaluating flue obstructions often require basic electrical test equipment and familiarity with furnace components. If you are not comfortable working inside the furnace cabinet or using a multimeter, it is best to contact a qualified HVAC technician.
Will resetting the furnace clear the 2+6 error code?
A power reset may temporarily clear the fault display, but if the underlying cause remains, the code will return at the next heating call or shortly after startup. The high fire pressure switch will be re-evaluated each time the furnace attempts to start, and if it is still reading closed before inducer activation, the fault will be triggered again. A reset is only a useful first step to confirm whether the fault is intermittent or consistent.