Lennox Furnace Error Code 3 Flashes

Pressure switch open with combustion air inducer energized (Control 103085).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 3 Flashes error code actually means

Your furnace detected that airflow through the heating system was not confirmed after the fan that creates that airflow started up. As a safety measure, the furnace stopped the ignition process to prevent unsafe operation. This usually means something is blocking the vents, a small hose connected to a sensor is loose or cracked, or the sensor itself has failed.

Diagnostic procedure

The full 3 Flashes procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check intake/exhaust vents for blockage; check pressure switch hoses and connections.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 3 Flashes procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 3 Flashes

Ranked by how often they cause this code
  1. 1Blocked intake or exhaust vents
  2. 2Damaged or disconnected pressure switch hose
  3. 3Failed pressure switch
  4. 4Weak or failing inducer motor
  5. 5Condensate blockage in pressure switch or tubing

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 3 Flashes

What does 3 Flashes mean on a Lennox furnace?
Three flashes on a Lennox furnace with Control 103085 means the pressure switch remained open while the combustion air inducer motor was energized. The pressure switch monitors draft airflow through the heat exchanger, and it must close its contacts when the inducer runs to confirm adequate airflow before ignition is allowed. When the switch stays open, the control board halts the heating cycle as a safety precaution. Common causes include blocked vents, a faulty pressure switch hose, or a failed pressure switch.
Is the 3 Flashes error on a Lennox furnace a safety concern?
Yes, but the error code itself means the furnace is behaving safely by refusing to ignite without confirmed airflow. The pressure switch exists specifically to prevent combustion from occurring if draft is inadequate, which could otherwise lead to carbon monoxide buildup in the living space. You should not attempt to bypass the pressure switch to restore heat. Address the underlying cause before operating the furnace.
Will resetting my Lennox furnace clear the 3 Flashes error?
A reset may temporarily clear the lockout and allow the furnace to attempt another ignition cycle, but if the underlying problem is not corrected the fault will return and the furnace will lock out again. Repeatedly resetting without diagnosing the cause does not fix the issue and can mask a condition that warrants attention. Diagnose and correct the source of the pressure switch fault before relying on the furnace for heat.
How do I fix the 3 Flashes error on my Lennox furnace?
Start by checking the intake and exhaust vent pipes at the exterior of your home for any blockage such as ice, snow, or debris. Next, trace the small rubber hose connecting the inducer housing to the pressure switch and look for cracks, kinks, or loose fittings. If the vents and hoses are clear and secure, the pressure switch itself or the inducer motor may need testing or replacement. A qualified technician can use a manometer to verify whether the inducer is producing adequate negative pressure and whether the switch is opening at the correct setpoint.
How much does it cost to repair a 3 Flashes error on a Lennox furnace?
Repair costs vary widely depending on the root cause. Clearing a blocked vent or reseating a loose pressure switch hose may cost nothing beyond a service call fee, typically in the range of $75 to $150. Replacing a pressure switch generally runs between $100 and $250 including parts and labor. An inducer motor replacement is the most expensive scenario, often ranging from $300 to $600 or more depending on the specific model and local labor rates.