Lennox Furnace Error Code 4 Flashes

Primary limit switch open (Control 103085).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 4 Flashes error code actually means

Your furnace detected that it was getting too hot inside and automatically shut off the burners to protect itself from damage. This is usually caused by something blocking airflow, like a dirty air filter or closed vents. The furnace will not run properly again until the cause of the overheating is found and fixed.

Diagnostic procedure

The full 4 Flashes procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for restricted airflow, dirty filter, or failed limit switch.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 4 Flashes procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 4 Flashes

Ranked by how often they cause this code
  1. 1Dirty or clogged air filter
  2. 2Blocked or closed supply and return vents
  3. 3Failed or underperforming blower motor
  4. 4Dirty blower wheel
  5. 5Failed primary limit switch

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 4 Flashes

What does 4 Flashes mean on a Lennox furnace?
Four flashes on a Lennox furnace indicate that the primary limit switch has opened, triggering a burner shutdown to prevent overheating. The primary limit switch is a thermal safety device that trips when the temperature around the heat exchanger rises above its rated threshold. This fault is associated with control board 103085. The furnace will not restart normally until the root cause of the overheating is addressed.
Is a 4 Flashes error on a Lennox furnace a safety concern?
Yes, the primary limit switch is a critical safety component designed to prevent heat exchanger overheating, which can lead to stress cracking over time. A cracked heat exchanger is a serious concern because it can allow combustion gases to mix with heated air distributed through the home. Do not disable or bypass the limit switch. Address the underlying cause of the fault before continuing to operate the furnace.
How much does it cost to repair a Lennox furnace showing 4 Flashes?
Repair cost depends on the specific cause. A replacement air filter typically costs between $5 and $30 and is a straightforward DIY task. Blower motor replacement generally runs between $200 and $600 including labor. A new primary limit switch is usually a lower-cost part, but total repair cost including a service call and labor typically falls in the $100 to $300 range for the switch alone.
How do I fix the 4 Flashes error on my Lennox furnace?
Start by replacing the air filter if it has not been changed recently, then check that all supply and return vents throughout the home are fully open and unobstructed. After correcting any airflow issues, allow the furnace to cool for 15 to 30 minutes so the limit switch can reset. If the error returns after restart, the blower motor, blower wheel, or limit switch itself may need professional inspection and possible replacement.
Will resetting my Lennox furnace clear the 4 Flashes error?
A manual reset may temporarily clear the fault and allow the furnace to restart, but if the underlying cause of restricted airflow or a failed limit switch is not corrected, the error will return, often within the same heating cycle. Repeated limit trips without correction accelerate wear on the heat exchanger and blower components. A reset should only be used after identifying and fixing the root cause.