What the 4+5 error code actually means

Your Lennox furnace detected that an internal safety switch stayed open for too long, which usually means the furnace was overheating and not cooling down fast enough. This is most often caused by a dirty air filter, a blocked vent, or a blower fan that is not working properly. The furnace shut itself off to prevent damage, and the underlying cause needs to be identified and corrected before it will operate safely again.

Diagnostic procedure

The full 4+5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for restricted airflow; check blower operation; check limit switches.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 4+5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 4+5

Ranked by how often they cause this code
  1. 1Restricted airflow from clogged filter or blocked registers
  2. 2Blower motor failure or reduced blower performance
  3. 3Failed or stuck-open high-limit switch
  4. 4Tripped auxiliary or rollout limit switch requiring manual reset
  5. 5Wiring fault between limit switch and control board 100869

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 4+5

What does 4+5 mean on a Lennox furnace?
The 4+5 flash code on a Lennox furnace with control board 100869 means the Watchguard circuit has detected that the high-limit switch stayed open for more than three consecutive minutes. The high-limit switch is a safety device that shuts off the burners when the furnace overheats. When it cannot reset within that three-minute window, the board locks out the burner and displays this code to indicate a persistent overheating or limit-circuit fault.
Is a Lennox 4+5 error code a safety concern?
Yes, this code should be taken seriously. The high-limit switch is a primary safety device that prevents the heat exchanger from overheating. Repeated overheating cycles can crack the heat exchanger over time, which can allow combustion gases to enter the living space. Do not simply reset and ignore this code without identifying and correcting the underlying cause.
How much does it cost to repair a Lennox furnace showing a 4+5 code?
Repair costs depend entirely on the root cause. A filter replacement costs only a few dollars and is a straightforward DIY task. A failed high-limit switch typically runs in the range of $100 to $300 installed, depending on labor rates in your area. A blower motor replacement is a more involved repair and can range from $300 to $700 or more depending on the motor type and local labor costs. Getting a diagnostic service call first is the best way to get an accurate estimate.
Can I fix a Lennox 4+5 error code myself?
Some causes of this code are DIY-friendly. Start by turning off the furnace, replacing the air filter, and confirming all supply and return registers are fully open. Check whether any manually-reset limit or rollout switches have a small button that has popped out and needs to be pressed back in. If the blower motor is not running or the filter and airflow checks do not resolve the issue, the repair moves into component testing that typically requires a qualified technician.
Will resetting the furnace clear a 4+5 error code?
A power reset may temporarily clear the lockout and allow the furnace to attempt operation again, but if the root cause has not been addressed, the limit switch will continue to trip and the 4+5 code will return. Resetting is useful for testing after completing a repair, but it is not a fix on its own. Repeated resets without resolving the underlying issue can accelerate heat exchanger wear.