What the 5 error code actually means

Your Lennox furnace tried to light the burner multiple times and failed every attempt, so it shut itself down as a safety precaution. This is called a lockout, and the furnace will wait about 60 minutes before it tries again on its own. The most likely causes are a worn-out igniter, a dirty flame sensor, or a problem with the gas supply.

Diagnostic procedure

The full 5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Wait 60-minute reset period; check ignitor, gas valve, and flame sensor.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5

Ranked by how often they cause this code
  1. 1Failed or degraded hot surface ignitor
  2. 2Dirty or corroded flame sensor
  3. 3Insufficient or interrupted gas supply
  4. 4Faulty gas valve
  5. 5Faulty or failing control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5

What does 5 mean on a Lennox furnace?
Error Code 5 on a Lennox furnace indicates a Watchguard lockout due to the burner failing to ignite after the maximum number of retries or recycles. The furnace control board monitors each ignition attempt and, if combustion is never confirmed by the flame sensor, it shuts the system down for safety. This code points to a problem in the ignition sequence involving the ignitor, flame sensor, gas valve, or gas supply. The furnace will remain locked out for approximately 60 minutes before attempting to restart.
Is it safe to run my furnace when it shows Error Code 5?
Error Code 5 means the furnace has already shut itself down as a safety precaution, so it is not actively running. The Watchguard lockout is designed specifically to prevent repeated failed ignition attempts that could cause unsafe gas accumulation. Do not attempt to repeatedly force restarts without identifying the root cause. If you smell gas in your home, leave immediately and contact your gas utility before troubleshooting.
How much does it cost to repair a Lennox furnace showing Error Code 5?
Repair costs depend on which component has failed. Flame sensor cleaning is a low-cost service call, typically in the range of $80 to $150 including labor. Replacing a hot surface ignitor generally costs between $100 and $250 for parts and labor. A faulty gas valve replacement can run from $200 to $600 depending on the model and labor rates. Control board replacement is typically the most expensive repair, ranging from $300 to $700 or more.
Can I reset my Lennox furnace to clear Error Code 5?
The furnace will automatically attempt to reset after the 60-minute Watchguard lockout period expires. You can also reset the furnace manually by turning the thermostat off and back on or by cycling the power at the breaker. However, if the underlying problem is not corrected, the furnace will fail to ignite again and return to lockout. Resetting without diagnosis and repair is only a temporary measure.
How do I fix Error Code 5 on a Lennox furnace?
Start by waiting for the 60-minute lockout period to expire, then inspect the hot surface ignitor for cracks and test its resistance. Clean the flame sensor rod with fine steel wool to remove oxidation buildup. Confirm that the gas supply valve is open and that gas pressure is adequate. If those steps do not resolve the issue, the gas valve or control board may need further testing or replacement by a qualified technician.