Lennox Furnace Error Code 5+2

Control failed self check, internal error; control will restart if error recovers (Board 100869).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 5+2 error code actually means

Your Lennox furnace's main control board ran an internal check on itself and found something wrong, so it shut down to prevent unsafe operation. The furnace may restart on its own if the problem was temporary, such as a brief power fluctuation. If it keeps showing this error and does not restart, the control board likely needs to be replaced.

Diagnostic procedure

The full 5+2 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5+2 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5+2

Ranked by how often they cause this code
  1. 1Faulty or failed control board (100869)
  2. 2Transient power supply issue
  3. 3Improper grounding
  4. 4Corrupted board firmware or memory
  5. 5Loose or corroded wiring connections to the board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5+2

What does 5+2 mean on a Lennox furnace?
The 5+2 flash code on a Lennox furnace means the control board (100869) has failed its internal self-check routine. This is an internal error originating within the board's own circuitry and logic, not in an external sensor or component. The board is designed to restart automatically if the fault condition clears on its own. If the error persists and the furnace does not recover, the control board likely needs to be replaced.
Is it safe to run my Lennox furnace when the 5+2 code is showing?
When the 5+2 code is active, the furnace control board has halted normal operation because it detected a fault in its own internal state. The furnace will not operate normally in this condition, so the risk of running it is low since it is essentially shut down. However, you should not attempt to bypass the error or force the system to run, as the board's self-check exists to prevent unsafe operation. Contact a technician to diagnose and resolve the fault before relying on the furnace for heating.
How much does it cost to fix a Lennox furnace showing the 5+2 error code?
If the fix requires replacing the control board (100869), costs typically range from a few hundred dollars to over five hundred dollars depending on part availability, labor rates in your area, and whether additional components are involved. If the cause turns out to be a wiring or power supply issue, costs may be significantly lower since no major parts are needed. Getting a diagnostic assessment from a licensed HVAC technician will give you an accurate estimate for your specific situation.
Can I fix the 5+2 error myself on a Lennox furnace?
Some basic checks are within reach for a knowledgeable homeowner, such as verifying the furnace has stable power, checking for tripped breakers, and inspecting visible wiring connections for looseness or corrosion. However, diagnosing a failed control board and replacing it involves working with line voltage and low-voltage control circuits, which is best handled by a qualified HVAC technician. Replacing the control board itself requires sourcing the correct part and properly transferring all wiring connections.
Will resetting the furnace clear the 5+2 error code?
The Lennox control board is designed to restart automatically if the fault condition that caused the 5+2 code resolves on its own, so a power cycle reset may temporarily clear the error if the cause was a transient power event. However, if the control board has a hardware failure, resetting the furnace will not resolve the underlying problem and the error will return. Repeated or persistent 5+2 codes after resets strongly indicate the control board needs replacement.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass