mypros+
Error code reference

Lennox Furnace Error Code 5+3

No Earth ground; control will restart if error recovers (Board 100869).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 5+3 error code actually means

Your Lennox furnace has detected that it is not properly connected to an electrical ground, which is a basic safety requirement for the unit to operate. The furnace will not run normally until this grounding issue is fixed. Once a proper ground is restored, the furnace should restart on its own without needing a manual reset.

Diagnostic procedure

The full 5+3 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check that the unit is properly grounded; install a proper main ground.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5+3 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5+3

Ranked by how often they cause this code
  1. 1Missing or disconnected ground wire at the furnace
  2. 2Broken or damaged ground conductor in the supply wiring
  3. 3Loose or missing ground connection at the electrical panel
  4. 4Corroded ground terminal at the furnace chassis
  5. 5Faulty control board 100869 ground sensing circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5+3

What does 5+3 mean on a Lennox furnace?
The 5+3 flash code on a Lennox furnace means the control board (model 100869) has detected no earth ground on the unit. The board monitors for a valid ground connection as part of its safety logic, and when none is found, it shuts down normal furnace operation. The code appears as five LED flashes, a pause, then three flashes. The furnace will attempt to restart automatically once the grounding problem is resolved.
Is the 5+3 error code a safety hazard?
Yes, a missing earth ground is a genuine electrical safety concern. Without a proper ground, fault current from a short circuit has no safe return path, which increases the risk of electric shock to anyone who contacts the furnace cabinet. The control board is designed to detect and flag this condition specifically to prevent operation under unsafe electrical conditions. Do not bypass or ignore this fault.
How much does it cost to fix a 5+3 grounding error on a Lennox furnace?
If the fix is simply tightening or reconnecting a loose ground wire at the furnace, costs are typically limited to a service call fee, which can range from around $75 to $150 depending on your area. If new wiring needs to be run from the panel to the furnace, or if the control board 100869 needs replacement, costs can range from $150 to $500 or more, factoring in parts and labor. Getting a diagnosis from a qualified technician before purchasing parts is strongly recommended.
Can I fix the 5+3 error code myself?
A knowledgeable DIYer can inspect the ground wire connections at the furnace chassis and confirm that a ground wire is present and secured. However, any work inside the electrical panel should be performed by a licensed electrician or HVAC technician, as exposed panel wiring carries lethal voltage. If the ground path checks out at the furnace end, have a qualified technician inspect the panel connection and verify continuity of the ground conductor.
Will resetting the furnace clear the 5+3 error?
A manual reset will not permanently clear this code because the control board will re-detect the missing ground and trigger the fault again. The 5+3 error is designed to recover automatically once the grounding condition is corrected, meaning no manual reset should be needed once the actual wiring problem is fixed. Repeatedly resetting the unit without addressing the ground issue will not resolve the fault.