What the 5+5 error code actually means

Your Lennox furnace is detecting that the low-voltage control power inside the unit has dropped too low to run safely. This is similar to a brownout condition inside the furnace itself. The good news is the furnace is designed to restart on its own once the voltage returns to a normal level.

Diagnostic procedure

The full 5+5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5+5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5+5

Ranked by how often they cause this code
  1. 1Failing or weak 24V transformer
  2. 2Overloaded 24V circuit from a shorted component
  3. 3Loose or corroded low-voltage wiring connections
  4. 4Low incoming line voltage to the furnace
  5. 5Defective control board with faulty voltage sensing

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5+5

What does 5+5 mean on a Lennox furnace?
The 5+5 error code on a Lennox furnace indicates that the 24-volt control circuit voltage has dropped below the level required for safe and reliable operation. The control board monitors this low-voltage circuit continuously and triggers this fault when it detects an undervoltage condition. The furnace will attempt to restart automatically once the voltage rises back to a normal level, so no manual reset is required if the root cause is resolved.
Is a Lennox 5+5 error code dangerous?
The 5+5 fault itself is a protective response by the furnace control board and is not inherently dangerous. The furnace shuts down operation to prevent unpredictable behavior from components that need stable voltage. The underlying cause, such as a shorted wire or component, should be identified and corrected to prevent repeated faults and potential damage to the transformer or control board over time.
How much does it cost to repair a Lennox furnace with a 5+5 error code?
Repair costs vary depending on the root cause. If only a loose wire connection needs attention, the cost may be limited to a service call fee, typically in the range of $75 to $150. Replacing a failed 24V transformer generally costs between $150 and $350 including parts and labor. If the control board itself is faulty, replacement costs can range from $300 to $700 or more depending on the specific board and labor rates in your area.
Can I fix a Lennox furnace 5+5 error code myself?
Some causes of the 5+5 code, such as loose low-voltage wiring connections, can be addressed by a knowledgeable DIYer comfortable working with low-voltage wiring. However, diagnosing and replacing a failing 24V transformer or identifying a shorted component drawing excess current requires a multimeter and familiarity with HVAC electrical systems. If you are not comfortable with electrical diagnostics, contacting a qualified HVAC technician is the safer route.
Will resetting the furnace clear a 5+5 error code?
The Lennox control board is designed to restart automatically once the 24V control circuit voltage returns to a normal operating level, so a manual reset is generally not necessary. If the underlying cause of the low voltage is still present after a reset, the fault will return quickly. Resetting without diagnosing and correcting the root cause is not a lasting solution.