Lennox Furnace Error Code 5+6

Low secondary (24VAC) voltage (Board 100869).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 5+6 error code actually means

Your Lennox furnace is detecting that the low-voltage power supply, which runs the controls and thermostat, is weaker than it should be. This is similar to a battery running low and not being able to properly power everything connected to it. The furnace shuts down as a safety measure because running with low control voltage can cause unreliable or unsafe operation.

Diagnostic procedure

The full 5+6 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5+6 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5+6

Ranked by how often they cause this code
  1. 1Overloaded 24VAC transformer
  2. 2Failing or undersized transformer
  3. 3Shorted or overloading low-voltage component
  4. 4Loose or corroded wiring connections
  5. 5Faulty control board 100869

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5+6

What does 5+6 mean on a Lennox furnace?
The 5+6 fault code on a Lennox furnace with control board 100869 indicates low secondary voltage on the 24VAC control circuit. This is the low-voltage power supply that runs the thermostat, control board, and components like the gas valve. The furnace flags this condition because insufficient control voltage can cause unreliable or unsafe operation. The root cause is typically a failing transformer, an overloaded secondary circuit, or a shorted low-voltage component.
Is a 5+6 fault on a Lennox furnace a safety concern?
Low 24VAC voltage can cause control components to behave unpredictably, which is why the furnace shuts down rather than continuing to run. It is not an immediately dangerous condition in the way a gas leak or carbon monoxide issue would be, but the furnace should not be forced to run while the fault is present. Have the underlying cause diagnosed and corrected before restoring normal operation.
Will resetting my Lennox furnace clear the 5+6 error code?
Resetting the furnace by cycling power may temporarily clear the fault display, but the code will return if the underlying low-voltage condition has not been resolved. The 5+6 code is triggered by an active electrical condition, not a one-time event, so it will continue to appear until the failing transformer, shorted component, or wiring issue is corrected. A reset alone is not a repair.
Can I fix a 5+6 error on my Lennox furnace myself?
Some diagnostic steps, such as inspecting wiring connections for corrosion or looseness, are within reach of a knowledgeable DIYer with a multimeter. However, measuring live transformer output voltage and isolating shorted components requires comfort working around electrical circuits. Replacing the transformer or control board 100869 involves handling line-voltage wiring and is generally best left to a qualified HVAC technician.
How much does it cost to repair a 5+6 error on a Lennox furnace?
Repair costs vary depending on the root cause. A replacement transformer typically runs in the range of $50 to $150 for the part, plus labor. If control board 100869 is the issue, board replacement costs are generally in the range of $150 to $400 or more for the part alone. A diagnostic service call from an HVAC technician to identify the specific cause usually adds $75 to $150 to the total cost.