What the 6 Flashes error code actually means

Your Lennox furnace has shut itself down because a safety sensor that monitors the exhaust venting system failed to confirm proper airflow during multiple heating attempts. The furnace locks out to protect your home from unsafe combustion conditions. A technician will need to inspect the venting system, the exhaust fan, and a small pressure-sensing switch to find and fix the root cause.

Diagnostic procedure

The full 6 Flashes procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check pressure switch, inducer operation, vent piping for obstruction.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 6 Flashes procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 6 Flashes

Ranked by how often they cause this code
  1. 1Blocked or obstructed vent piping
  2. 2Failed or stuck pressure switch
  3. 3Cracked or disconnected pressure switch hose
  4. 4Inducer motor failure or weak performance
  5. 5Waterlogged condensate trap or blocked drain

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 6 Flashes

What does 6 Flashes mean on a Lennox furnace?
Six flashes on a Lennox furnace with control board 103085 indicates a pressure switch cycle lockout. This means the furnace attempted to start multiple times but the pressure switch repeatedly failed to confirm proper draft from the inducer motor. The control board locks the system out as a safety measure. The vent piping, inducer motor, and pressure switch are the primary areas to inspect.
Will resetting the furnace clear the 6 Flashes lockout?
Resetting the furnace by cycling the power or thermostat may temporarily clear the lockout and allow the furnace to attempt ignition again. However, if the underlying problem is not corrected, the pressure switch fault will recur and the lockout will return, possibly after just one or two heating cycles. A reset without repair is not a solution.
How much does it cost to repair a Lennox furnace showing 6 Flashes?
Repair costs vary depending on the root cause. Clearing a blocked vent or condensate drain may cost between $75 and $200 in labor if performed by a technician. Replacing a pressure switch typically runs between $100 and $250 including parts and labor. An inducer motor replacement is a more significant repair, generally ranging from $300 to $600 or more depending on the specific motor and local labor rates.
Can I fix a 6 Flashes error on my Lennox furnace myself?
Some causes of this error are DIY-accessible, such as clearing a blocked exterior vent termination, reconnecting a loose pressure switch hose, or clearing a clogged condensate drain. However, testing the pressure switch with a manometer, evaluating inducer motor performance, or replacing components requires basic HVAC tools and comfort working with furnace components. If you are unsure, having a qualified technician diagnose the fault is the safer choice.
Is a 6 Flashes error on a Lennox furnace a safety concern?
Yes, this code represents the furnace protecting itself and your home from potentially unsafe operating conditions. The pressure switch exists to confirm that combustion gases are being properly vented before ignition proceeds. Running the furnace with a compromised venting system or a faulty pressure switch can create risks including incomplete combustion or inadequate flue gas exhaust. Do not attempt to bypass the pressure switch to force the furnace to run.