What the DIAG#1: Alternate Flash / DIAG#2: Alternate Flash error code actually means

Your furnace tried to light the burners but could not detect a flame, so it shut itself down as a safety measure. This could be caused by a gas supply issue, a worn-out igniter, or a dirty flame sensor. The furnace will not restart on its own until the underlying problem is corrected.

Diagnostic procedure

The full DIAG#1: Alternate Flash / DIAG#2: Alternate Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check gas supply, gas valve wiring, and ignition system.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DIAG#1: Alternate Flash / DIAG#2: Alternate Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DIAG#1: Alternate Flash / DIAG#2: Alternate Flash

Ranked by how often they cause this code
  1. 1No or insufficient gas supply
  2. 2Dirty or failed flame sensor
  3. 3Faulty hot surface ignitor
  4. 4Gas valve wiring fault or failed gas valve
  5. 5Draft inducer or pressure switch issue

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DIAG#1: Alternate Flash / DIAG#2: Alternate Flash

What does DIAG#1: Alternate Flash / DIAG#2: Alternate Flash mean on a Lennox furnace?
This alternating flash pattern on both diagnostic LEDs indicates a Watchguard lockout caused by the burners failing to ignite. The furnace attempted to light the burners one or more times but could not confirm a flame, so the control board shut down the system as a safety precaution. The furnace will remain locked out until the ignition problem is identified and corrected.
Is it safe to keep using my furnace when this error code is showing?
The furnace is already locked out and will not produce heat or release gas while this code is active, so there is no immediate danger from continued failed ignition attempts. However, you should not attempt to bypass or override the Watchguard lockout. The lockout exists to prevent unburned gas accumulation, and the root cause should be diagnosed and repaired before the system is returned to normal operation.
How much does it cost to repair a Lennox furnace with a burner ignition fault?
Repair costs vary depending on the failed component. Flame sensor cleaning or replacement is typically the least expensive fix, often falling in the range of $75 to $200 including labor. A hot surface ignitor replacement generally runs $150 to $350. Gas valve replacement is more involved and can range from $300 to $600 or more depending on the part and local labor rates. A service call for diagnosis alone usually costs $80 to $150 before any parts.
How do I fix the Watchguard burner ignition fault on my Lennox furnace?
Start by confirming the gas supply is on and that other gas appliances are working. Then inspect the flame sensor for buildup and clean it if needed. Check the hot surface ignitor for visible cracks and test the gas valve wiring for continuity. If basic checks do not resolve the issue, a qualified technician should measure gas pressure and test the ignition system components under live conditions.
Will resetting the furnace clear this error code?
A manual reset by cycling power to the furnace may clear the lockout temporarily and allow one more ignition sequence to run. However, if the underlying cause is not corrected, the furnace will fail to ignite again and return to lockout. Resetting without repairing the problem is not a long-term solution and repeated lockout cycles can stress system components.