Lennox Furnace Error Code DIAG#1: Continuous On / DIAG#2: Continuous On

Circuit board self-check failure or ignition/blower control is wired incorrectly.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DIAG#1: Continuous On / DIAG#2: Continuous On error code actually means

Your Lennox furnace's control board is detecting a serious internal problem with itself or a wiring mistake in how key components are connected. The furnace is not able to start or run safely until this is resolved. Turning the power off and back on may clear the issue if it was a temporary glitch, but if the error returns, a technician will need to inspect the wiring or replace the control board.

Diagnostic procedure

The full DIAG#1: Continuous On / DIAG#2: Continuous On procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Reset control by turning main power off.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DIAG#1: Continuous On / DIAG#2: Continuous On procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DIAG#1: Continuous On / DIAG#2: Continuous On

Ranked by how often they cause this code
  1. 1Incorrect ignition or blower control wiring
  2. 2Control board self-check failure
  3. 3Transient power interruption or voltage spike
  4. 4Loose or disconnected control wiring
  5. 5Failed ignition or blower control component

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DIAG#1: Continuous On / DIAG#2: Continuous On

What does DIAG#1: Continuous On / DIAG#2: Continuous On mean on a Lennox furnace?
This fault code means the furnace control board has detected either a failure in its own internal self-check routine or a wiring error on the ignition or blower control circuit. Both diagnostic indicator LEDs staying continuously lit together is the board's way of flagging this specific condition. The furnace will not operate normally until the cause is identified and corrected. A power reset is the recommended first step in the diagnostic process.
Is it safe to run my Lennox furnace when both DIAG lights are continuously on?
No, the furnace should not be operated when this fault is active. The continuous illumination of both diagnostic LEDs indicates the control board cannot confirm its own circuit integrity or has detected an invalid wiring condition. Running the furnace in this state bypasses the safety logic the board is designed to enforce. Power should be turned off and the system should be inspected before attempting further operation.
How much does it cost to repair a Lennox furnace showing this control board fault?
Repair costs depend on the root cause. If the issue is a wiring correction only, you may pay only for a diagnostic service call, typically in the range of $75 to $150. If the control board requires replacement, parts and labor combined generally range from $300 to $600 or more depending on the specific model and local labor rates. Getting a diagnostic assessment first is the most cost-effective approach before authorizing any parts replacement.
Will resetting the power clear the DIAG#1 and DIAG#2 continuous on fault on my Lennox furnace?
Turning the main power off and back on is the first recommended diagnostic step and may clear the fault if it was caused by a transient power event. If the fault returns immediately after the reset, a wiring problem or a failed control board is the more likely cause. A reset alone will not fix an underlying hardware or wiring issue, so further inspection is necessary if the error reappears.
How do I fix the continuous DIAG#1 and DIAG#2 fault on a Lennox furnace?
Start by turning the main power off, waiting a moment, and then restoring power to reset the control board. If the fault clears and does not return, the issue was likely a transient event. If the fault returns, inspect all wiring connections to the ignition control and blower control terminals and compare them to the unit's wiring diagram. If wiring checks out correctly and the fault persists, the control board itself may need to be replaced.