Lennox Furnace Error Code DIAG#1: Flash / DIAG#2: Off

Pressure switch Watchguard

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DIAG#1: Flash / DIAG#2: Off error code actually means

Your Lennox furnace has shut itself down because a safety sensor called the pressure switch detected that airflow through the system was not working correctly during a heating cycle. This is often caused by something blocking the pipes that bring in air or exhaust fumes, or by a clogged drain line that removes water from the system. The furnace will not restart until the underlying problem is found and corrected.

Diagnostic procedure

The full DIAG#1: Flash / DIAG#2: Off procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check that pressure switch is open without combustion air blower operating; check for blocked inlet/exhaust vent or condensate line.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DIAG#1: Flash / DIAG#2: Off procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DIAG#1: Flash / DIAG#2: Off

Ranked by how often they cause this code
  1. 1Blocked condensate drain line
  2. 2Blocked or restricted inlet or exhaust vent
  3. 3Failed or weak pressure switch
  4. 4Cracked or disconnected pressure switch tubing
  5. 5Weak or failing inducer motor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DIAG#1: Flash / DIAG#2: Off

What does DIAG#1: Flash / DIAG#2: Off mean on a Lennox furnace?
This code indicates a Pressure Switch Watchguard fault, meaning the pressure switch opened while the furnace was actively running. The pressure switch monitors the draft created by the combustion air blower, and if it loses that signal mid-cycle, the control board shuts the furnace down as a safety precaution. The most common triggers are a blocked condensate drain, a restricted vent pipe, or a faulty pressure switch. The furnace will continue to lockout until the root cause is corrected.
Is it safe to run my Lennox furnace when this error code is showing?
No. The Pressure Switch Watchguard is a safety lockout designed to prevent the furnace from operating when combustion airflow is compromised. Running the furnace with a blocked vent or condensate problem could allow combustion gases to accumulate in unsafe locations. Leave the furnace off until the fault is diagnosed and corrected.
How much does it cost to repair a Lennox furnace showing this pressure switch error?
If the fix is simply clearing a blocked condensate drain or removing a vent obstruction, out-of-pocket costs can be minimal, typically covering only a service call fee in the range of $75 to $150. If the pressure switch itself needs replacement, parts and labor generally run between $150 and $350 depending on the specific switch and local labor rates. Inducer motor replacement is the most expensive scenario, often ranging from $400 to $800 or more including parts and labor.
How do I fix the DIAG#1: Flash / DIAG#2: Off error on my Lennox furnace?
Start by checking the condensate drain line and trap for blockages and clearing any standing water or buildup. Next, inspect the inlet and exhaust vent pipes at their exterior terminations for ice, debris, or physical damage. If those are clear, examine the pressure switch hose for cracks or loose connections and test the pressure switch itself for proper continuity and pull-in pressure. If the switch is faulty or the inducer motor is weak, those components will need to be replaced.
Will resetting the furnace clear the DIAG#1: Flash / DIAG#2: Off code?
Resetting the furnace may temporarily clear the lockout and allow it to attempt another heating cycle, but the code will return if the underlying problem has not been fixed. The Watchguard circuit is designed to detect repeated pressure switch dropouts, and continued resets without resolving the cause can lead to longer lockout periods. Address the root cause before resetting.