Lennox Furnace Error Code DS1 On / DS2 Off

Main power polarity reversed; switch line and neutral.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS1 On / DS2 Off error code actually means

Your furnace's electrical wiring has been connected backwards, with the hot and neutral wires swapped at the point where power enters the unit. This is a wiring problem, not a broken part, and your furnace detected it automatically to protect itself. An electrician or HVAC technician can fix this quickly by switching those two wires to their correct positions.

Diagnostic procedure

The full DS1 On / DS2 Off procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Reverse the line and neutral at the 120V field connection.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS1 On / DS2 Off procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS1 On / DS2 Off

Ranked by how often they cause this code
  1. 1Reversed line and neutral at furnace field wiring connection
  2. 2Reversed wiring at an upstream junction box or disconnect
  3. 3Incorrectly wired outlet or circuit at the electrical panel
  4. 4Wire labeling error after prior service work

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS1 On / DS2 Off

What does DS1 On / DS2 Off mean on a Lennox furnace?
This diagnostic code means the 120V main power supply to the furnace has reversed polarity, with the line (hot) and neutral wires connected to the wrong terminals. The furnace control board uses the DS1 and DS2 diagnostic switches to detect this condition. The fix is to swap the line and neutral wires at the 120V field connection point on the furnace after turning off power at the breaker.
Is reversed polarity on a Lennox furnace dangerous?
Yes, reversed polarity is a genuine electrical safety concern and should be corrected promptly. Beyond the risk to the furnace control board and flame sensing components, reversed polarity means the neutral side of the circuit carries line voltage, which creates shock hazards during servicing. The furnace's diagnostic system flags this condition specifically because it can affect safe operation of the unit.
How much does it cost to fix a reversed polarity fault on a Lennox furnace?
If the issue is isolated to the furnace field wiring connection, an HVAC technician can typically resolve it in under an hour, putting labor costs in the range of roughly $75 to $150 depending on your area and service provider. No replacement parts are needed in most cases since this is a wiring correction. If the reversed polarity originates at the electrical panel or a junction box, an electrician may need to be involved, which could add to the overall cost.
Can I fix the DS1 On / DS2 Off polarity error myself?
This repair involves working with 120V wiring, so it should only be attempted by someone comfortable with electrical work and proper lockout procedures. The fix itself is straightforward: shut off the breaker, identify the line and neutral wires at the furnace field connection, swap them to the correct terminals, and restore power. If you are unsure which wire is the hot (line) conductor, use a non-contact voltage tester or multimeter before making any changes, or contact a licensed HVAC technician.
Will resetting the furnace clear the DS1 On / DS2 Off code?
No, simply resetting the furnace will not clear this fault. The DS1 On / DS2 Off condition is detected continuously based on the live electrical wiring, so the code will persist every time the furnace powers up until the line and neutral wires are correctly swapped at the 120V field connection. The fault must be corrected at the source before normal operation can resume.