Lennox Furnace Error Code DS1 On / DS2 On

Circuit board failure or control wired incorrectly; check 24 and 115 volts to board.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS1 On / DS2 On error code actually means

Your Lennox furnace is showing a fault that points to a problem with its main control board, which is the brain of the furnace. Either the board has failed internally, or something in the wiring connected to it is set up incorrectly. A technician will need to check the electrical supply to the board and inspect the wiring to determine the exact cause.

Diagnostic procedure

The full DS1 On / DS2 On procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check 24V and 115V supply to control board; replace board if voltages are correct.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS1 On / DS2 On procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS1 On / DS2 On

Ranked by how often they cause this code
  1. 1Failed Integrated Furnace Control Board
  2. 2Missing or Low 115V AC Supply
  3. 3Missing or Low 24V AC Supply
  4. 4Incorrect Control Wiring
  5. 5Loose or Corroded Board Connections

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS1 On / DS2 On

What does DS1 On / DS2 On mean on a Lennox furnace?
This code means the furnace control board has detected a condition consistent with a board failure or an incorrect wiring configuration. DS1 and DS2 are diagnostic indicators on the integrated furnace control board, and both being active simultaneously is a signal that the board cannot operate normally. The diagnostic process begins with checking that the board is receiving both 24V and 115V AC, then inspecting the control wiring before replacing the board.
Is it safe to run my furnace when it shows the DS1 On / DS2 On code?
When the DS1 On / DS2 On fault is active, the furnace control board is not functioning correctly and the furnace will typically not operate. Attempting to force operation is not advisable because the board manages critical safety functions including limit switches and ignition sequencing. Leave the furnace off until the fault is diagnosed and resolved.
How much does it cost to repair the DS1 On / DS2 On fault on a Lennox furnace?
Repair cost depends on the root cause. If the fix is simply tightening a loose connection or correcting a wiring error, a service call fee of roughly $80 to $150 may be all that is needed. If the integrated furnace control board requires replacement, parts alone typically range from $150 to $400 or more depending on the specific board, with additional labor costs on top of that. Getting a diagnostic visit from a licensed HVAC technician will clarify the exact cause and provide a firm repair estimate.
Can I fix the DS1 On / DS2 On error code myself?
A knowledgeable DIYer can safely check whether the furnace circuit breaker is on and inspect visible wiring connections for obvious problems. However, confirming 115V and 24V supply voltages at the board requires a multimeter and comfort working around live electrical circuits, which carries real shock risk. Replacing the control board is a more advanced repair that requires matching the correct replacement part and carefully reconnecting all wiring harnesses. If you are not experienced with electrical diagnostics, a licensed HVAC technician is the safer choice.
Will resetting the furnace clear the DS1 On / DS2 On error?
A power reset may temporarily clear the code, but if the underlying cause is a failed control board or a wiring error, the fault will return as soon as the board attempts to operate. A reset is a reasonable first step to confirm whether the fault is intermittent, but it does not repair a failed board or fix a wiring problem. Proper diagnosis of the voltage supply and wiring is necessary for a lasting fix.