Lennox Furnace Error Code DS1 Slow Flash / DS2 ON

Primary, secondary, backup secondary or rollout limit switch open; limits must close within 3 minutes or unit goes into 1 hour Watchguard.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS1 Slow Flash / DS2 ON error code actually means

Your Lennox furnace has detected that one of its internal safety switches has tripped, likely because something is causing the furnace to overheat or because flames are not staying where they should. The furnace shuts itself down to prevent damage and will stay off for up to an hour if the problem is not corrected. The most common reason this happens is a clogged air filter or blocked airflow, so checking and replacing the filter is a good first step.

Diagnostic procedure

The full DS1 Slow Flash / DS2 ON procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check continuity across limit switches; check for restrictions on blower inlet air (including filter) and outlet air.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS1 Slow Flash / DS2 ON procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS1 Slow Flash / DS2 ON

Ranked by how often they cause this code
  1. 1Clogged or restricted air filter
  2. 2Blocked blower inlet or outlet
  3. 3Blower motor failure or reduced speed
  4. 4Failed or stuck limit switch
  5. 5Blocked or restricted flue or venting

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS1 Slow Flash / DS2 ON

What does DS1 Slow Flash / DS2 ON mean on a Lennox furnace?
This code means that one or more limit switches, including the primary, secondary, backup secondary, or rollout limit switch, has opened during operation. These switches are safety devices that trip when they detect overheating or flame rollout. If the switch does not close again within 3 minutes, the furnace enters a 1-hour Watchguard lockout and suspends heating. The root cause is usually restricted airflow or a faulty limit switch.
Will resetting my Lennox furnace clear this error code?
Resetting the furnace can clear the 1-hour Watchguard lockout and allow the unit to attempt another heating cycle, but it will not fix the underlying problem. If the cause of the limit switch opening is not corrected, the fault will return and the lockout will activate again. Identifying and resolving the root cause, such as restricted airflow or a failed switch, is necessary for a permanent fix.
How much does it cost to repair a Lennox furnace showing this error code?
If the fix is simply replacing a clogged air filter, the cost is minimal, typically a few dollars to around twenty dollars for a filter. If a limit switch or rollout switch needs replacement, parts and labor generally range from around one hundred fifty dollars to three hundred fifty dollars depending on the switch type and local labor rates. A failed blower motor is a more significant repair and can range from three hundred dollars to over six hundred dollars including labor. Getting a diagnosis from a qualified technician will clarify which component is at fault.
How do I fix the DS1 Slow Flash / DS2 ON code on my Lennox furnace?
Start by checking and replacing the air filter, then inspect the blower inlet and all supply and return registers for obstructions. Use a multimeter to check continuity across each limit switch and rollout switch to identify any that are open and not resetting. If airflow is adequate and the switches still will not close, one or more switches may need to be replaced. Also inspect the flue and venting system for blockages that could cause abnormal heat buildup.
Is it safe to run my furnace with the DS1 Slow Flash / DS2 ON code active?
The furnace is designed to shut down when this code is active, which is the safe behavior. You should not attempt to bypass or defeat the limit switches, as they protect the heat exchanger and the home from overheating and potential fire hazards. Flame rollout in particular can indicate a serious combustion problem that requires inspection before the furnace is returned to service.