Lennox Furnace Error Code DS1/DS2 Alternating Fast Flash

During ignitor warm-up only

During ignitor warm-up only: improper main ground, broken ignitor or open ignitor circuit, or line voltage below 75 volts.

First step from the service manual

Check ground, ignitor resistance (10.9-19.7 ohms for 18M34), and line voltage.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.