Lennox Furnace Error Code E 227

Low pressure switch open during trial for ignition or run mode.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E 227 error code actually means

Your Lennox furnace detected that it was not building enough airflow inside the venting system to safely start or keep the burners running. The furnace shut itself off as a safety precaution. A technician will need to check the venting, the exhaust fan, and a pressure-sensing safety switch to find out why the airflow is insufficient.

Diagnostic procedure

The full E 227 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check pressure (inches w.c.) of low pressure switch closing on heat call. Measure operating pressure. Inspect vent and combustion air inducer for correct operation and restriction. Resumes normal operation after fault is cleared.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E 227 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E 227

Ranked by how often they cause this code
  1. 1Blocked or restricted vent piping
  2. 2Failed or weak inducer motor
  3. 3Dirty or restricted inducer wheel
  4. 4Defective or failed low pressure switch
  5. 5Cracked, disconnected, or blocked pressure tubing

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E 227

What does E 227 mean on a Lennox furnace?
E 227 means the low pressure switch was detected in the open position during the trial for ignition or while the furnace was actively running. The low pressure switch must close to confirm that the inducer is creating adequate draft before and during combustion. When it does not close, the furnace shuts down as a safety measure. The fault clears and normal operation resumes automatically once the underlying issue is corrected.
Is E 227 on a Lennox furnace a safety concern?
Yes, but the safety system is working as intended when E 227 appears. The furnace is refusing to run because it cannot confirm proper venting conditions, which prevents the risk of combustion without adequate draft. You should not attempt to bypass or override the low pressure switch. Leave the furnace off until the root cause is repaired.
How much does it cost to repair a Lennox furnace showing E 227?
Repair cost depends entirely on what is causing the fault. Clearing a blocked vent termination may cost only a service call fee, typically in the range of $75 to $150. Replacing a low pressure switch generally runs $100 to $250 including parts and labor. An inducer motor replacement is a more significant repair and can range from $300 to $600 or more depending on the model and local labor rates.
Can I fix E 227 on my Lennox furnace myself?
Some causes of E 227 are accessible to a knowledgeable DIYer. Checking the vent termination for ice, debris, or blockage and inspecting visible pressure tubing for cracks or loose connections are reasonable first steps. However, measuring switch closing pressure with a manometer, testing the inducer motor and capacitor, and replacing components requires tools and experience that most homeowners do not have. If basic visual checks do not reveal an obvious problem, a qualified HVAC technician should complete the diagnosis.
Will resetting my Lennox furnace clear the E 227 code?
According to Lennox, the furnace resumes normal operation automatically after the fault is cleared, meaning the underlying pressure issue must be resolved first. Simply cycling power or pressing a reset button without correcting the venting or inducer problem will result in E 227 returning as soon as the furnace attempts another heating cycle. Clearing the code is only meaningful after the root cause has been identified and fixed.