Lennox Furnace Error Code E113

High line voltage detected (voltage higher than nameplate rating).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E113 error code actually means

Your Lennox furnace has detected that the electrical voltage coming into the unit is higher than it is designed to handle, so it shut itself down to avoid damage. This is similar to a surge protector tripping to protect your electronics. Once the voltage from your home's electrical supply returns to a normal level, the furnace will restart on its own within a few seconds.

Diagnostic procedure

The full E113 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Provide power voltage within proper range. System resumes normal operation 5 seconds after fault recovered.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E113 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E113

Ranked by how often they cause this code
  1. 1Utility power supply overvoltage
  2. 2Lost neutral at the electrical service panel
  3. 3Wiring error following recent electrical work
  4. 4Faulty or incorrectly rated step-up transformer
  5. 5Defective furnace control board giving false reading

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E113

What does E113 mean on a Lennox furnace?
E113 means the furnace control board has detected that incoming line voltage is higher than the unit's nameplate rating. The furnace shuts down automatically to protect its electrical components from damage caused by overvoltage. The system will resume normal operation on its own approximately 5 seconds after the voltage returns to an acceptable level. The fault points to an issue with the electrical supply rather than a mechanical component inside the furnace.
Is the E113 error on a Lennox furnace a safety concern?
Yes, persistent overvoltage is a legitimate safety and equipment concern. Sustained high voltage can overheat motor windings, degrade insulation on electrical components, and shorten the lifespan of the control board and other electronics. A lost neutral condition at the electrical panel, which is one potential cause, is a serious electrical hazard that can damage appliances throughout the home and should be addressed by a licensed electrician immediately.
How much does it cost to repair an E113 error on a Lennox furnace?
The repair cost depends entirely on the root cause. If the issue is a utility supply problem, your utility company may correct it at no charge. If a licensed electrician is needed to repair a panel connection or fix a wiring error, expect costs in the range of $100 to $400 or more depending on the complexity of the work. If the furnace control board itself has failed and needs replacement, parts and labor typically range from $300 to $700.
How do I fix the E113 error on my Lennox furnace?
Start by measuring the actual line voltage at the furnace disconnect or power junction using a true-RMS voltmeter and comparing it to the voltage listed on the furnace nameplate. If voltage is elevated, check your home's main panel for loose connections and contact your utility provider to report a possible transformer issue. If all supply voltages measure correctly, suspect the furnace control board's voltage-sensing circuit and consult a certified HVAC technician for further diagnosis.
Will resetting my Lennox furnace clear the E113 code?
A manual reset is not required for E113. The furnace will automatically clear the fault and resume normal operation within 5 seconds once the incoming voltage drops back into the acceptable range. If you power cycle the furnace while the overvoltage condition still exists, the error will return immediately. The underlying supply voltage problem must be corrected first.