Low 24V power (range is 18 to 30 volts); control will restart if the error recovers.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E115 error code actually means

Your Lennox furnace is detecting that the low-voltage electrical supply powering its controls has dropped too low to operate safely. This is often caused by a weak or overloaded transformer inside the furnace. The furnace will try to restart on its own once the voltage returns to normal, but you will likely need a technician to find and fix the root cause.

Diagnostic procedure

The full E115 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check and correct voltage. Check for additional power-robbing equipment connected to system. May require installation of larger VA transformer.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E115 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E115

Ranked by how often they cause this code
  1. 1Overloaded 24V transformer
  2. 2Failing or weak transformer
  3. 3Loose or corroded low-voltage wiring connection
  4. 4Undersized transformer for system configuration
  5. 5Short circuit or grounding fault in low-voltage wiring

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E115

What does E115 mean on a Lennox furnace?
E115 indicates that the 24-volt control circuit voltage has dropped below 18 volts, which is outside the acceptable operating range of 18 to 30 volts. The furnace control board monitors this supply voltage and shuts down operation when it falls too low to ensure reliable control function. The error will self-clear and the furnace will attempt a restart once voltage recovers to an acceptable level. A technician should identify and correct the cause of the low voltage to prevent the error from recurring.
Is an E115 error on a Lennox furnace a safety hazard?
The E115 code itself reflects a control circuit voltage issue rather than a direct safety hazard such as a gas or carbon monoxide problem. The furnace shuts down to protect its controls from operating in an unreliable state. However, because the furnace will not heat properly while this error is active, the condition should be corrected promptly, especially in cold weather, to maintain safe indoor temperatures.
How much does it cost to repair an E115 error on a Lennox furnace?
Repair costs depend on the root cause. If the fix is simply tightening a loose connection or removing an unnecessary accessory from the low-voltage circuit, service call fees alone may apply, typically in the range of 75 to 150 dollars. If a new transformer is needed, parts and labor combined generally range from 150 to 350 dollars, depending on the transformer VA rating required and local labor rates. Upgrading to a higher-capacity transformer or rewiring for additional zones may increase costs further.
Will resetting the furnace clear the E115 error?
The E115 error is designed to self-clear once the 24-volt supply voltage returns to within the 18 to 30 volt acceptable range, so a manual reset may temporarily clear the code. However, if the underlying cause of the voltage drop is not addressed, the error will return once the furnace attempts normal operation and the low-voltage circuit is again placed under load. A reset alone is not a repair.
How do I fix the E115 error on my Lennox furnace?
Start by measuring the actual voltage at the 24-volt transformer secondary terminals and at the control board input using a multimeter. Check for any smart thermostats, humidistats, zone controllers, or other accessories recently added to the system that could be increasing the load on the transformer. If the transformer output is low under load, it may need to be replaced or upgraded to a higher VA rating. A licensed HVAC technician should perform this diagnosis to ensure accurate voltage measurements and safe component replacement.