Lennox Furnace Error Code E124

Active communicating thermostat signal missing for more than 3 minutes.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E124 error code actually means

Your Lennox furnace lost contact with the thermostat for more than 3 minutes and stopped receiving the instructions it needs to operate. This is usually caused by a loose wire connection between the thermostat and the furnace. Checking and reseating the wiring and then restarting the thermostat is the first step toward getting the system running again.

Diagnostic procedure

The full E124 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check four wiring connections, ohm wires and cycle power at the thermostat.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E124 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E124

Ranked by how often they cause this code
  1. 1Loose or disconnected wiring at the thermostat or furnace
  2. 2Broken or damaged communication wire
  3. 3Thermostat has lost power or experienced an internal fault
  4. 4Incompatible or non-communicating thermostat installed
  5. 5Faulty furnace control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E124

What does E124 mean on a Lennox furnace?
E124 means the furnace control board has not received a valid signal from the communicating thermostat for more than 3 minutes. Lennox communicating systems rely on a continuous digital data link over a four-wire connection, and any interruption longer than 3 minutes triggers this fault. The furnace will suspend normal operation until communication is restored. The most common causes are loose wiring connections or a power issue at the thermostat.
Will resetting the furnace clear the E124 error code?
Cycling power at the thermostat is the recommended reset step for E124 and can clear the fault if the communication loss was caused by a temporary signal disruption. However, if an underlying wiring problem or component failure is present, the code will return after the reset. Always inspect and ohm the four-wire communication wiring before relying on a power cycle as a solution.
How much does it cost to repair a Lennox furnace showing E124?
If the fix is simply reseating a loose wire connection, there may be no parts cost involved, with a service call typically ranging from $75 to $150 depending on your area. If the communication wire run needs replacement, parts and labor costs can range from $100 to $300. A failed communicating thermostat replacement can range from $200 to $600 depending on the specific model, and a furnace control board replacement can range from $300 to $700 including labor.
How do I fix error code E124 on my Lennox furnace?
Start by inspecting all four wiring connections at the thermostat and at the furnace control board, making sure every wire is firmly seated at the correct terminal. Use a multimeter to ohm out each wire individually to check for continuity and rule out a broken conductor. After confirming the wiring is intact, cycle power at the thermostat to allow the communication link to reinitialize. If the error persists after these steps, the thermostat or the furnace control board may require replacement.
Is the E124 error code on a Lennox furnace a safety hazard?
E124 is a communication fault rather than a combustion or pressure safety fault, so it does not indicate an immediate danger such as a gas leak or carbon monoxide risk. However, the furnace may not operate properly while the fault is active, which means it may not heat your home. The issue should be diagnosed and resolved promptly, especially during cold weather, to restore normal heating operation.