Lennox Furnace Error Code E221

Low pressure switch failed open.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E221 error code actually means

Your Lennox furnace is detecting that a safety switch responsible for confirming proper airflow through the system is not closing when it should. This usually means there is a blockage somewhere in the venting, an issue with the fan that moves combustion gases out of the furnace, or the safety switch itself has failed. The furnace shuts down automatically to prevent unsafe operating conditions until the problem is resolved.

Diagnostic procedure

The full E221 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check inches of water column pressure during operation of low pressure switch on heat call, measure operating pressure, inspect vent and combustion air inducer for correct operation and restriction.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E221 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E221

Ranked by how often they cause this code
  1. 1Blocked or restricted flue vent
  2. 2Blocked combustion air intake pipe
  3. 3Clogged pressure switch hose or port
  4. 4Failing or weak inducer motor
  5. 5Defective low pressure switch

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E221

What does E221 mean on a Lennox furnace?
E221 means the low pressure switch has failed to close or has opened unexpectedly during a heating call. This switch monitors the negative pressure created by the inducer motor to confirm proper draft conditions before allowing the furnace to continue the ignition sequence. When the control board does not detect switch closure, it locks out the furnace and displays E221. The fault points to a venting issue, inducer problem, or a faulty pressure switch.
Is it safe to run my furnace with the E221 code showing?
No. The E221 lockout exists specifically to prevent the furnace from operating under conditions where combustion gases may not be properly exhausted. Running the furnace while this fault is present could create a risk of carbon monoxide buildup inside the home. The system should remain off until the underlying cause is identified and corrected.
How much does it cost to repair an E221 error on a Lennox furnace?
Repair costs vary depending on the root cause. Clearing a blocked vent or intake pipe may cost only a service call fee, typically in the range of $75 to $150. Replacing a defective low pressure switch is generally a lower-cost repair, often ranging from $100 to $250 including parts and labor. Inducer motor replacement is more involved and can range from $300 to $600 or more depending on the specific motor and local labor rates.
Can I fix the E221 error myself, or do I need a technician?
Some causes of E221 are accessible to a knowledgeable homeowner, such as clearing a blocked vent termination, removing ice from the intake pipe, or draining a clogged pressure switch hose. However, measuring water column pressure at the switch port, evaluating inducer motor performance, and replacing components require tools and skills that typically call for a qualified HVAC technician. If basic visual checks of the venting do not reveal an obvious blockage, professional diagnosis is recommended.
Will resetting the furnace clear the E221 code?
A reset may temporarily clear the code and allow the furnace to attempt another heating cycle, but E221 will return if the underlying problem has not been resolved. If the venting restriction, inducer issue, or failed pressure switch is still present, the control board will detect the open switch again and re-enter lockout. Resetting is useful for confirming whether the fault is intermittent, but it is not a repair.