Lennox Furnace Error Code E223

High pressure switch failed open.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E223 error code actually means

Your Lennox furnace has detected that a safety switch in the venting system did not activate the way it should when the furnace tried to start. This switch is designed to confirm that air is moving correctly through the vents before allowing the burners to ignite. The furnace has shut itself down as a precaution until the issue is identified and corrected.

Diagnostic procedure

The full E223 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check inches of water column pressure of high pressure switch on heat call, measure operating pressure, inspect vent and combustion air inducer for correct operation and restriction.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E223 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E223

Ranked by how often they cause this code
  1. 1Blocked or restricted vent pipes
  2. 2Failing combustion air inducer motor
  3. 3Disconnected, cracked, or blocked pressure tubing
  4. 4Condensate drain blockage
  5. 5Defective high pressure switch

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E223

What does E223 mean on a Lennox furnace?
E223 means the high pressure switch failed to close during a heat call. This switch is part of the inducer and venting safety circuit and must detect adequate pressure from the combustion air inducer before the furnace is allowed to ignite. When the switch stays open instead of closing, the control board locks out the heating cycle and displays E223. The cause can range from a venting restriction to a faulty inducer motor or a defective switch.
Is it safe to keep using my furnace when E223 is displayed?
No. When E223 is active, the furnace has locked out and will not ignite, which means the system is already preventing operation as a safety measure. You should not attempt to bypass or override the lockout. The error indicates a fault in the venting or pressure sensing circuit, and running the furnace without resolving it could create unsafe combustion or venting conditions. Leave the furnace off and have it inspected before restoring operation.
How much does it cost to repair an E223 error on a Lennox furnace?
Repair costs vary widely depending on the cause. Clearing a blocked vent or drain line may cost between $75 and $200 for a service call and labor. Replacing a high pressure switch typically runs between $100 and $300 including parts and labor. Replacing a combustion air inducer motor is more involved, with costs generally ranging from $300 to $700 or more depending on the motor and labor rates in your area.
Can I fix an E223 error on my Lennox furnace myself?
Some of the simpler causes, such as clearing a blocked vent termination, reconnecting a loose pressure tube, or clearing a clogged condensate drain, are tasks a capable DIYer can handle safely. However, measuring inches of water column pressure at the switch, evaluating inducer motor performance, and replacing components like the pressure switch or inducer motor are best handled by a qualified HVAC technician. Attempting repairs without proper tools or knowledge of combustion systems carries safety risks.
Will resetting my Lennox furnace clear the E223 code?
A manual reset may temporarily clear the fault and allow the furnace to attempt another heat cycle, but if the underlying cause has not been corrected, the E223 error will return. Repeated resets without addressing the root cause can sometimes worsen component wear, particularly on the inducer motor. A reset is only useful as part of diagnostics, not as a long-term solution.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started