Lennox Furnace Error Code E252

Discharge air temperature too high (gas heat only).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E252 error code actually means

Your Lennox furnace is detecting that the air coming out of the heating system is getting too hot, which can damage the furnace and your ductwork over time. This is usually caused by something blocking the airflow, like a dirty filter, or by the furnace burning more gas than it should. The furnace has shut down to protect itself and needs to be inspected before it runs safely again.

Diagnostic procedure

The full E252 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check temperature rise, air flow and input rate.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E252 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E252

Ranked by how often they cause this code
  1. 1Restricted or Insufficient Airflow
  2. 2Incorrect Gas Input Rate
  3. 3Blower Motor Failure or Reduced Speed
  4. 4Undersized or Poorly Designed Ductwork
  5. 5Cracked or Obstructed Heat Exchanger

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E252

What does E252 mean on a Lennox furnace?
E252 indicates that the discharge air temperature in gas heating mode has exceeded the safe upper limit. The furnace control board monitors the temperature of air leaving the heat exchanger, and when it gets too high, the system shuts down and displays E252. The most common causes are restricted airflow, an elevated gas input rate, or a blower problem. The issue must be diagnosed and corrected before the furnace will operate safely.
Is E252 on a Lennox furnace a safety concern?
Yes, E252 should be treated as a safety-related fault. Excessive discharge air temperatures can stress and eventually crack the heat exchanger, which can allow combustion gases including carbon monoxide to enter the living space. The furnace's automatic shutdown is a protective response, and running the unit repeatedly while the fault is unresolved increases the risk of permanent heat exchanger damage.
How much does it cost to repair a Lennox furnace E252 error?
Repair costs depend entirely on the root cause. If a dirty filter or blocked register is the problem, there is little to no cost beyond a replacement filter, which typically runs a few dollars to around twenty dollars. A blower motor capacitor replacement may cost in the range of fifty to one hundred fifty dollars in parts and labor. Blower motor replacement or heat exchanger repair can range from several hundred to over one thousand dollars depending on the component and local labor rates.
How do I fix E252 on my Lennox furnace?
Start by checking and replacing the air filter, then confirm that all supply and return registers throughout the home are open and unobstructed. If the filter is clean and airflow appears normal, a technician will need to measure temperature rise, verify manifold gas pressure, and test blower motor performance. Do not continue operating the furnace repeatedly until the root cause is identified, as sustained high discharge temperatures can damage the heat exchanger.
Will resetting the furnace clear the E252 error?
Resetting the furnace may temporarily clear the E252 code and allow the unit to start again, but the error will return if the underlying cause has not been corrected. Simply resetting without addressing airflow, gas input, or blower issues does not resolve the problem. Repeated resets while the fault condition persists can accelerate wear on the heat exchanger and other components.