mypros+
Error code reference

Lennox Furnace Error Code E262

Soft lockout

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E262 error code actually means

Your Lennox furnace tried to start several times but kept failing because a safety sensor detected a problem with airflow or venting, so it shut itself down to prevent unsafe operation. The furnace is in a temporary lockout state and may restart on its own after a waiting period, but the underlying issue needs to be fixed or it will happen again. A technician should check the venting system, the blower that exhausts combustion gases, and the sensor that monitors that process.

Diagnostic procedure

The full E262 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
See E223 and E225.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E262 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E262

Ranked by how often they cause this code
  1. 1Blocked or restricted flue or intake pipe
  2. 2Weak or failed inducer motor
  3. 3Clogged or waterlogged condensate trap
  4. 4Cracked, disconnected, or blocked pressure switch hose
  5. 5Faulty pressure switch

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E262

What does E262 mean on a Lennox furnace?
E262 means the furnace has entered a soft lockout after exceeding the maximum number of ignition recycle attempts, with the last failure caused by the pressure switch opening. The pressure switch monitors whether the inducer motor is creating proper airflow for safe venting. The furnace shuts down to prevent unsafe operation, but it may attempt to restart automatically after a timeout period. The underlying pressure switch fault must be identified and corrected to prevent recurrence.
Is it safe to run my furnace when it shows E262?
The furnace is already preventing itself from operating by entering a soft lockout, so it is not actively running in an unsafe state. However, you should not repeatedly reset the unit to force it to run while the fault remains unresolved. The pressure switch system exists to confirm that combustion gases are being properly exhausted, and bypassing or ignoring that protection can create a carbon monoxide risk.
What other error codes are related to E262 on a Lennox furnace?
E262 specifically directs technicians to investigate E223 and E225, as those codes describe the actual pressure switch fault conditions that accumulate into the E262 lockout. E223 typically relates to the pressure switch failing to close during the pre-ignition sequence, while E225 relates to the pressure switch opening after ignition. Resolving E262 requires diagnosing and clearing whichever of those underlying faults is occurring.
Can I reset the furnace to clear the E262 error?
Because E262 is a soft lockout, the furnace will eventually attempt to restart on its own without a manual reset. Cycling power to the furnace may clear the lockout temporarily, but if the root cause involving the pressure switch or venting system is not addressed, the furnace will accumulate failed cycles and return to lockout. A reset is not a fix, it only buys time before the fault reoccurs.
How much does it cost to repair an E262 error on a Lennox furnace?
Repair costs depend entirely on the root cause. Clearing a blocked flue or condensate trap is typically a low-cost service call ranging from roughly $80 to $200. Replacing a pressure switch generally falls in the $150 to $350 range including parts and labor. An inducer motor replacement is more involved, with costs commonly ranging from $400 to $900 or more depending on the specific furnace model and local labor rates.