Lennox Furnace Error Code E295

Indoor blower motor temperature is too high (motor tripped on internal protector).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E295 error code actually means

Your furnace's indoor blower motor got too hot and shut itself off to prevent damage. This is similar to a circuit breaker tripping, but it happens inside the motor itself. The furnace will not run properly until the motor cools down and the root cause of the overheating is fixed.

Diagnostic procedure

The full E295 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check motor bearings and amps. Replace if necessary.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E295 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E295

Ranked by how often they cause this code
  1. 1Worn or failing motor bearings
  2. 2Motor drawing excessive amperage
  3. 3Restricted airflow reducing motor cooling
  4. 4Winding insulation breakdown
  5. 5Incorrect motor speed setting or capacitor fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E295

What does E295 mean on a Lennox furnace?
E295 means the indoor blower motor temperature became too high and the motor's internal thermal overload protector tripped to prevent damage. The furnace shuts down blower operation when this occurs. The root cause is typically worn bearings, elevated amp draw, or restricted airflow that prevents adequate motor cooling.
Is it safe to keep running my furnace with an E295 error?
Continuing to operate the furnace with a tripping blower motor is not advisable. The blower circulates heat away from the heat exchanger, and without proper airflow, the heat exchanger can overheat and potentially crack over time. Address the E295 error before returning the furnace to normal use.
How much does it cost to fix a Lennox furnace E295 error?
Costs vary depending on the cause. If only a filter replacement or minor airflow correction is needed, the expense is minimal. A run capacitor replacement typically falls in the range of $75 to $200 including labor. Full blower motor replacement generally ranges from $300 to $700 or more depending on the specific motor, labor rates, and your location.
Can I fix E295 myself or do I need a technician?
Checking and replacing the air filter is something most homeowners can handle. However, testing motor amperage, inspecting bearings, and replacing the blower motor require electrical knowledge and proper tools. It is generally recommended to have a qualified HVAC technician perform the amp draw test and any motor replacement to ensure safe and accurate diagnosis.
Will resetting the furnace clear the E295 error?
Resetting the furnace may temporarily clear the code if the motor's internal protector has cooled and reset on its own. However, if the underlying cause such as worn bearings or high amp draw is not corrected, the motor will overheat again and E295 will return. A reset without repair is only a short-term measure.