Lennox Furnace Error Code E303

LSOM

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E303 error code actually means

Your Lennox system is detecting a problem with the compressor, the part of your heating and cooling system that circulates refrigerant. Either the compressor is failing to start properly and is getting stuck, or it is turning on and off too quickly without running long enough to do its job. This needs to be diagnosed by a qualified technician, as continued operation can permanently damage the compressor.

Diagnostic procedure

The full E303 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E303 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E303

Ranked by how often they cause this code
  1. 1Failed start or run capacitor
  2. 2Low refrigerant charge
  3. 3Seized or mechanically failed compressor
  4. 4Faulty or pitted contactor
  5. 5LSOM module fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E303

What does E303 mean on a Lennox furnace?
E303 is a fault code generated by the Load Shed Output Module (LSOM) indicating either a locked compressor rotor or compressor short cycling, meaning the compressor is running for less than 4 minutes per cycle. A locked rotor means the compressor motor is receiving power but cannot rotate. Both conditions signal a potentially serious problem with the compressor or supporting components that requires professional diagnosis.
Will resetting the furnace clear the E303 code?
Resetting the furnace may temporarily clear the E303 code, but if the underlying fault with the compressor or supporting components is not repaired, the code will return quickly. Repeatedly resetting and restarting a compressor in a locked rotor condition can cause serious and permanent damage to the motor windings. It is best to leave the system off and have a technician diagnose the root cause before attempting a reset.
How much does it cost to repair a Lennox E303 error code?
Repair costs vary widely depending on the root cause. Replacing a failed capacitor is typically a relatively low-cost repair, often in the range of $150 to $400 including labor. A contactor replacement falls in a similar range. If the compressor itself is seized or failed, replacement costs can range from $1,200 to $2,800 or more depending on the unit size and refrigerant type. A refrigerant recharge and leak repair generally falls somewhere in between those two extremes.
Can I fix E303 on my Lennox furnace myself?
Most of the underlying causes for E303 require professional tools and certifications to address properly. Refrigerant handling requires an EPA Section 608 certification, and safely measuring locked rotor amperage requires a clamp meter and knowledge of electrical safety. A homeowner can visually inspect the contactor for obvious burn marks, but capacitor replacement and refrigerant work should be left to a certified HVAC technician.
Is it safe to run my Lennox system with an E303 error code active?
No, continuing to operate the system with an active E303 code is not recommended. A locked rotor condition creates extremely high current draw that can overheat and burn out compressor windings in a very short time. Even if the fault is short cycling, repeated starts and stops stress the compressor motor and can cause it to fail prematurely. Shut the system down and schedule a service call promptly.