What the E370 error code actually means

Your Lennox furnace detected that a safety switch, which monitors whether a door or panel on the furnace is properly closed, has been open for too long. The furnace shut itself down as a precaution to prevent unsafe operation. Check that all furnace access panels and doors are fully closed and latched, which may allow the system to reset.

Diagnostic procedure

The full E370 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Terminate all services and wait for interlock switch to close. Alarm clears when 24VAC is continuously sensed on DS terminal for minimum 10 seconds or on power reset.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E370 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E370

Ranked by how often they cause this code
  1. 1Access panel or door not fully closed
  2. 2Faulty or worn interlock switch
  3. 3Damaged or disconnected wiring in the interlock circuit
  4. 4Control board DS terminal fault
  5. 5Debris or obstruction preventing panel closure

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E370

What does E370 mean on a Lennox furnace?
E370 means the furnace detected that its interlock switch was in the open position for two continuous minutes. The interlock switch monitors whether access panels and doors are properly closed. The furnace shuts down when this safety circuit is open to prevent unsafe operation. The alarm clears when 24VAC is continuously sensed on the DS terminal for at least 10 seconds, or after a power reset.
Is error code E370 on a Lennox furnace a safety concern?
Yes, the interlock switch circuit is a safety feature designed to prevent the furnace from operating with access panels open or unsecured. The E370 alarm indicates this safety loop is broken, which is why the furnace shuts down automatically. Do not attempt to bypass or defeat the interlock switch, as it protects against exposure to high-voltage components, combustion gases, and moving parts.
How much does it cost to repair a Lennox furnace showing error E370?
If the fix is simply reseating a loose access panel, there is no parts cost and minimal labor involved. If the interlock switch itself needs replacement, parts typically range from around $15 to $60 depending on the specific switch, plus any labor charges. A control board replacement, if required in more serious cases, can range from $200 to $600 or more for parts alone. Having a qualified HVAC technician diagnose the specific cause first will help avoid unnecessary parts costs.
How do I fix error code E370 on my Lennox furnace?
Start by terminating any active service operations and checking that all furnace access panels and doors are fully closed and properly latched. If the panels are secure and the error persists, a technician should test the interlock switch for proper mechanical actuation and verify that 24VAC is present on the DS terminal on the control board. Faulty switches or wiring in the interlock circuit will need to be repaired or replaced.
Will resetting the furnace clear the E370 error?
A power reset can clear the E370 alarm, but the alarm will return if the underlying cause is not corrected. The alarm also clears automatically if 24VAC is continuously present on the DS terminal for a minimum of 10 seconds after the interlock switch closes. Simply resetting without addressing the root cause will result in the error returning once the furnace attempts to operate again.