mypros+
Error code reference

Lennox Furnace Error Code E405

LSOM

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E405 error code actually means

Your Lennox system detected that the air conditioner compressor lost power or could not run due to a break in its electrical circuit. This could be caused by something as simple as a tripped breaker or a blown fuse near the outdoor unit. Once the power issue is fixed and the compressor runs through one complete normal cycle, the error message will go away on its own.

Diagnostic procedure

The full E405 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Clears after 1 normal compressor run cycle.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E405 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E405

Ranked by how often they cause this code
  1. 1Tripped circuit breaker
  2. 2Blown fuse at disconnect or unit
  3. 3Power disconnection at outdoor unit
  4. 4Utility power interruption
  5. 5Faulty contactor or wiring issue

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E405

What does E405 mean on a Lennox furnace?
E405 indicates that the Lennox System Operations Monitor detected an open circuit at the compressor, meaning the compressor lost its electrical path and could not run. This is typically caused by a power disconnection, a tripped breaker, or a blown fuse rather than a failed compressor. The fault is logged automatically when the compressor fails to complete a normal run cycle. Once the power issue is resolved and the compressor runs one full cycle, the error clears on its own.
Will resetting the furnace clear the E405 error code?
A manual reset of the control board is not required to clear E405. The fault clears automatically after the compressor successfully completes one normal run cycle. However, if the underlying cause, such as a blown fuse or tripped breaker, has not been corrected, the error will return because the compressor still cannot operate.
How much does it cost to repair an E405 error on a Lennox system?
If the cause is simply a tripped breaker, there is no parts cost involved. Replacing fuses at the disconnect typically costs between $10 and $50 for parts. If the fault is traced to a failed contactor or damaged wiring, repair costs including labor can range from $150 to $400 depending on the component and local service rates.
How do I fix error code E405 on my Lennox system?
Start by checking the circuit breaker dedicated to the outdoor unit at your main electrical panel and reset it if tripped. Next, inspect the disconnect box near the outdoor unit for blown fuses, replacing any that test open with a multimeter. Once power is restored to the compressor circuit, allow the system to run through a complete cooling cycle, which will clear the fault automatically.
Is E405 on a Lennox system a safety concern?
E405 itself is not a safety hazard, but working on the electrical components involved does carry risk. Always shut off power at the disconnect and breaker before inspecting fuses, contactors, or wiring at the outdoor unit. If you are not comfortable working with line-voltage electrical components, contact a qualified HVAC technician.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass