What the E406 error code actually means

Your Lennox furnace has detected that the compressor is not starting up properly because the system is not seeing the expected electrical activity when the compressor tries to kick on. This could be caused by a faulty start capacitor, a bad relay, or a wiring problem. Until the underlying issue is fixed, the heating and cooling system will not operate normally.

Diagnostic procedure

The full E406 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Required amount of current is not passing through Start current transformer. Clears after current is sensed in START sensor, or after power reset.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E406 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E406

Ranked by how often they cause this code
  1. 1Failed start capacitor
  2. 2Defective start relay or potential relay
  3. 3Loose or corroded wiring at compressor terminals
  4. 4Open compressor start winding
  5. 5Faulty START current transformer or sensor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E406

What does E406 mean on a Lennox furnace?
E406 on a Lennox furnace indicates that the LSOM (Lennox System Operation Monitor) has detected an open start circuit on the compressor. The control board monitors current through a Start current transformer and triggers this fault when the required current is not detected during a compressor startup attempt. This fault will clear once current is properly sensed in the START sensor, or after a power reset is performed.
Is it safe to keep running my furnace with an E406 error?
When E406 is active, the system has already halted compressor operation to prevent damage, so the compressor is not running. Continuing to attempt restarts without diagnosing the root cause risks damaging the compressor further, particularly if the start winding is drawing excessive current during failed start attempts. It is best to stop cycling the unit and have the system inspected promptly.
How much does it cost to repair an E406 error on a Lennox furnace?
Repair costs vary significantly depending on the failed component. Replacing a start capacitor is generally an inexpensive repair, typically ranging from $75 to $200 including labor. A start relay replacement falls in a similar range. If the compressor itself has a failed start winding, replacement costs can range from $1,000 to $2,500 or more depending on unit size and refrigerant type, making a full system replacement worth considering in those cases.
Can I fix an E406 error on my Lennox furnace myself?
Some basic checks, such as inspecting wiring connections at the compressor terminals for looseness or corrosion, can be done by a knowledgeable homeowner. However, testing and replacing components like start capacitors, relays, or current transformers involves working with high-voltage circuits and should be performed by a qualified HVAC technician. Attempting repairs without proper training and equipment carries serious safety risks.
Will resetting the power clear an E406 fault on my Lennox furnace?
A power reset will clear the E406 fault code, and the code will also clear automatically if current is properly detected in the START sensor circuit on the next startup attempt. However, if the underlying problem is not corrected, the fault will return when the compressor attempts to start again. Clearing the code without diagnosing and repairing the cause is only a temporary measure.