What the LED Flashing 2 sec on 2 sec off error code actually means

Your Lennox furnace started a heating cycle, got a flame going, but then the flame went out on its own before the heating was finished. The furnace is now waiting 60 seconds before it tries to light again. If this keeps happening, you will need a technician to find out why the flame keeps going out.

Diagnostic procedure

The full LED Flashing 2 sec on 2 sec off procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED Flashing 2 sec on 2 sec off procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED Flashing 2 sec on 2 sec off

Ranked by how often they cause this code
  1. 1Dirty or Failing Flame Sensor
  2. 2Gas Supply Pressure Fluctuation
  3. 3Dirty or Partially Blocked Burners
  4. 4Cracked or Compromised Heat Exchanger
  5. 5Faulty Burner Control Board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED Flashing 2 sec on 2 sec off

What does LED Flashing 2 sec on 2 sec off mean on a Lennox furnace?
This flash pattern indicates the burner control has entered Recycle mode. The furnace detected that the flame went out during an active heating cycle and is now holding in a 60-second delay before attempting to relight. It is not a full lockout, but it signals an intermittent combustion problem that should be diagnosed. If the condition repeats, the furnace may escalate to a lockout fault.
Will resetting my Lennox furnace clear the LED Flashing 2 sec on 2 sec off code?
A power reset may allow the furnace to attempt another ignition cycle, and the flashing code may temporarily stop if the restart is successful. However, resetting does not fix the underlying cause of the flame loss. If the root issue is not corrected, the furnace will lose the flame again and return to Recycle mode or progress to a full lockout condition.
How much does it cost to repair a Lennox furnace showing the LED Flashing 2 sec on 2 sec off code?
Repair costs vary widely depending on the root cause. Cleaning the flame sensor is often included in a diagnostic service call, which typically ranges from $75 to $150. Replacing a flame sensor part can add $20 to $80 in parts. A new gas valve or control board can bring total repair costs to $300 to $700 or more, and heat exchanger replacement is significantly more expensive, sometimes approaching the cost of a new furnace.
Can I fix the LED Flashing 2 sec on 2 sec off code myself on a Lennox furnace?
A homeowner can safely inspect and clean the flame sensor rod, check that the air filter is not heavily clogged, and ensure the gas shutoff valve is fully open. However, checking gas pressure, inspecting the heat exchanger for cracks, and replacing control components require specialized tools and should be handled by a licensed HVAC technician. Attempting gas valve or heat exchanger repairs without proper training carries serious safety risks.
Is it safe to run my Lennox furnace while it shows the LED Flashing 2 sec on 2 sec off code?
The furnace may continue to attempt restarts on its own, but running it repeatedly with an unresolved flame loss condition is not recommended. If the cause is a cracked heat exchanger, continued operation could allow combustion gases to enter the living space, which is a carbon monoxide hazard. Have the furnace inspected by a qualified technician before relying on it for extended heating.