Lennox Furnace Error Code LED1 ALT FAST FLASH / LED2 ALT FAST FLASH

During ignitor warm-up

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED1 ALT FAST FLASH / LED2 ALT FAST FLASH error code actually means

Your furnace is having trouble with the part that lights the burner, or there may be an electrical issue preventing it from working properly. This could mean the igniter is broken, there is a wiring problem, or the power coming into the furnace is too low. A technician will need to test the igniter and check your electrical connections to determine the exact cause.

Diagnostic procedure

The full LED1 ALT FAST FLASH / LED2 ALT FAST FLASH procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check ignitor resistance (10.9-19.7 ohms); check main ground; check line voltage above 75V.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1 ALT FAST FLASH / LED2 ALT FAST FLASH procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1 ALT FAST FLASH / LED2 ALT FAST FLASH

Ranked by how often they cause this code
  1. 1Failed or broken ignitor
  2. 2Improper or loose main ground connection
  3. 3Line voltage below 75 volts
  4. 4Incorrectly wired control board
  5. 5Circuit board failure

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1 ALT FAST FLASH / LED2 ALT FAST FLASH

What does LED1 ALT FAST FLASH / LED2 ALT FAST FLASH mean on a Lennox furnace?
This alternating fast flash pattern from both LED indicators signals a fault tied to the ignitor circuit or a board-level issue. During ignitor warm-up, it indicates a broken ignitor, open ignitor circuit, bad main ground, or line voltage below 75 volts. When it appears at power-up, it points to a circuit board failure or incorrect control wiring. The timing of when the code appears is key to directing the diagnosis correctly.
Is it safe to run my Lennox furnace when this error code is active?
No, you should not attempt to operate the furnace while this code is active. If the ignitor circuit is open or the line voltage is below the minimum threshold, the burner will not light reliably. Repeated failed ignition attempts can cause unburned gas to accumulate, which is a safety hazard. Address the underlying fault before restoring normal furnace operation.
How much does it cost to repair the LED1 ALT FAST FLASH / LED2 ALT FAST FLASH error on a Lennox furnace?
Repair costs depend heavily on the root cause. Ignitor replacement is typically the least expensive fix, with parts generally ranging from roughly $20 to $80 and labor adding to that total depending on your market. A failed control board is the most expensive scenario, with board costs typically ranging from $150 to $400 or more before labor. If the fault is simply a loose ground wire or a low-voltage supply issue from the electrical panel, the repair cost may be limited to a service call fee.
How do I fix the LED1 ALT FAST FLASH / LED2 ALT FAST FLASH error on my Lennox furnace?
Start by measuring the ignitor resistance with a multimeter. A healthy ignitor reads between 10.9 and 19.7 ohms. If the reading is outside that range or shows an open circuit, the ignitor needs replacement. Also check that the main ground connection is secure and that line voltage at the furnace is above 75 volts. If the code appears only at power-up, inspect the control board wiring before suspecting board failure.
Will resetting my Lennox furnace clear the LED1 ALT FAST FLASH / LED2 ALT FAST FLASH error?
A power cycle may temporarily clear the fault display, but if the underlying problem is not corrected the code will return as soon as the furnace attempts another ignition cycle. Resetting the unit without repairing the ignitor, ground connection, or voltage issue will not produce a lasting fix. If the fault appears immediately at power-up after a reset, the control board wiring or the board itself requires attention.